Laserfiche WebLink
DEC -16 -2009 16:18 <br /> • 70948.01- 109-47 <br /> Architectural Testing Page6of9 <br /> Test Results: (Continued) <br /> Paragraph Title of Test - Test Method Results Allowed <br /> Test Specimen #'x: H -R30 1219 x x,256 (48 x 90) (Flange) (Continued) <br /> • <br /> 5.3.6.3 Deglazing Test <br /> In remaining direction - 230 N (50 lbs) <br /> Right stile 2.3 mm (0.09 ") 11.4 nun (0.45 ") <br /> , Left stile 2.0 mm (0.08 ") 11.4 min (0.45 ") <br /> Optional Performance <br /> 4.4.2.6 Water Penetration Resistance per ASTM E 547 <br /> (with and without insect screen) <br /> 330 Pa (6.90 psf) No leakage No leakage <br /> 4,4.2.6 Uniform Load Deflection per ASTM E 330 <br /> (Deflections were talon, on the meeting rail) <br /> (Loads were held for 52 seconds) <br /> 1440 Pa (30.09 psf) ,( itive) 18.0 mm (0.71") See Note #3 • <br /> 1440 Pa (30.09 psf) (negative) 16.3 nun (0.64 ") See Note #3 <br /> Note #3: The defections reported are not limited by AAMA/WDMA/CSA 101/X.S.2/A440 -05 <br /> for this product designation. The deft ection data is recorded in this report for special code <br /> compliance and information only. ' <br /> 4.4.2.6 Uniform Load Structu*al,per ASTM E 330 <br /> (Permanent sets were;'talcen on the meeting rail) <br /> (Loads were held for 40 seconds) <br /> 2160 Pa (45.14 psf) (positive) 3.6 nnn (0.14 ") 4.6 min (0.18 ") max. <br /> 2160 Pa (45.14 psf) (negative) 0.76 mm (0.03 ") 4.6 min (0.18 ") max. <br /> Test Specimen #2: H -R35 1219x, 2286 (48 x 90) (Fin) <br /> Optional Performance <br /> 4.4.2.6 Water Penetration,Reaistaice per ASTM E 547 <br /> (with and without insect screen) <br /> 330 Pa (6.90 psf) No leakage No leakage <br />