Laserfiche WebLink
• <br /> • <br /> FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR r . <br /> Street: Permit Office: e i4tt 04 ?q 1 1 r h: 11 <br /> City, State, Zip: TAMPA , FL , Permit Number. 46,y y <br /> Owner. LENNAR Jurisdiction: 61i(, <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 998.67 ft <br /> 2. Single family or multiple family Multi family <br /> b. WA R= ft <br /> 3. Number of units, if multiple family 1 c. N/A <br /> R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A <br /> a. U- Factor. Dbl, U=0.60 182.25 ft <br /> R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor. WA ft a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: <br /> SEER: 14 <br /> d. U- Factor: N/A ft2 13. Heating systems <br /> SHGC: <br /> e. U- Factor. N/A ft2 a. Electric Heat Pump Cap: 28 kBtu/hr <br /> SHGC: HSPF: 8.2 <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 a. Electric Cap: 40 gallons <br /> b. N/A R= ft2 EF: 0.92 <br /> c. N/A R= ft2 b. Conservation features <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.133 Total As -Built Modified Loads: 33.08 PASS <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and THE Sr <br /> this calculation are in compliance with the Florida Energy specifications covered by this .\' . % e ? � ' 4: - <br /> PREPARED : "l �' j , - � . - Before construction is completed V 1 with the Florida Energy Code /...47 : , "ss r .. ` <br /> RED B lib ' m�� ,�r �.,;; 00 'gy •.. <br /> - - [ ��� ,., <br /> DATE: this building will be inspected for t7 a p <br /> compliance with Section 553.908 t <br /> o <br /> I hereby certify that this building, as design I� ' • mpliance Florida Statutes. <br /> with the Florida Energy Code. CO <br /> OWNER/AGENT: / <br /> BUILDING OFFICIAL: <br /> DATE: %� DATE: /D- /7_ _f77 <br /> . �� ._ <br /> - Compliance requires certificati • by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3124/20091:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />