Laserfiche WebLink
• <br /> 'FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, hp: TAMPA , FL , Permit Number: <br /> Owner: LENNAR Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 998.67 ft' <br /> 2. Single family or multiple family Multi- family <br /> 3. Number of units, if multiple family 1 b. N/A R fP <br /> c. N/A R= f <br /> 4. Number of Bedrooms 3 <br /> d. N/A R= ft' <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> ft <br /> 7. Windows Description plea b. N/A R= <br /> a. U- Factor. Dbl, U =0.60 182.25 ft' c. N/A R= ft' <br /> SHGC: SHGC=0.32 11. Ducts <br /> b. U- Factor. N/A ft' a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor: N/A ft' a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: <br /> SEER: 14 <br /> d. U- Factor. N/A ft2 13. Heating systems <br /> SHGC: <br /> a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor. N/A ft' <br /> SHGC: HSPF: 8.2 <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area y <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 112 a. Electric Cap: 40 gallons <br /> ft <br /> b. N/A R= ft' EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft2 <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.133 <br /> Total As -Built Modified Loads: 33.08 PASS <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and CF' B <br /> ... 67 : 41 .1i.' . .... <br /> this calculation are in compliance with the Florida Energy specifications covered by this y <br /> Code. calculation indicates compliance ' co i / ,�''` `' i ' <br /> PREPARED 8 t C t _ _ with the Florida Energy Code. im • <br /> ,, '4* �� "'�+ ." `: <br /> _ . Before constr is completed _ .. _ <br /> DATE: flt_ � "- �" ., � "� i~' <br /> this building will be inspected for .....--...z <br /> compliance with Section 553.908 ; �• a <br /> • <br /> I hereby certify that this building, as desig *. • • pliance Florida Statutes. r.f+' "� * <br /> with the Florida Energy Code. - ~ 1 C V <br /> OWNER/AGENT: / � <br /> BUILDING OFFICI • L: .... <br /> DATE: L-Y 1 DATE: 1 ,.,r " / <br /> i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/242009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />