Laserfiche WebLink
a . <br /> FORM 1100A -08 ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street Permit Office: e,% i-t.i o-c 2-epLj r h ; I IS <br /> City, State, Zip: TAMPA , FL , Permit Number: q(„ 55 <br /> Owner. LENNAR HOMES Jurisdiction: (, 11 (p o <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft <br /> 2. Single family or multiple family Multi- family <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c. N/A R= <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. WA R= ft2 <br /> 7. Windows Description Area c. N/A R= ft2 <br /> a. U- Factor. Dbl, U =0.60 119.64 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U-Factor: N/A ft2 13. Heating systems <br /> SHGC: <br /> a. Electric Heat Pump <br /> e. U- Factor. WA ft2 p Cap: 34 kBtu/hr <br /> SHGC: HSPF: 8.2 <br /> 8. Floor T 14. Hot water systems <br /> Ypes Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab-On -Grade Edge Insulation R =0.0 1531.00 ft <br /> b. Raised Floor R =19.0 88.00 ft2 EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft= None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.100 Total As -Built Modified Loads: 30.62 PASS <br /> Total Baseline Loads: 38.54 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and THE ............ <br /> T <br /> this calculation are in compliance sp ecifications covered by this <br /> the Florida Energy 0 � . . ATE:' •. <br /> ./. ' <br /> Code. calculation indicates compliance y w',i„ � `• \ �� �o <br /> with the Florida Energy Code. h ; n,,, :} i �' "� O ` <br /> DATE: ARED BY: ��' _ _ 'L ,L _ Before construction is com pleted • a . : <br /> .-di o.... �. .� ,, 7° <br /> � <br /> this building will be inspecte for i O `"�` a <br /> compliance with Section 553.908 <br /> 1 hereby certify that I is • uilding, as d; z _= is in • • mpliance Florida Statutes. <br /> .0 <br /> with the Florida Energy Code. F' COD - <br /> OWNER/AGENT: BUILDING OFFICIAL: / 5/ <br /> DATE: �� DATE: 43 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />