Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number. <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft <br /> 2. Single family or multiple family Multi- family <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> c. N/A R= fF <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft' <br /> b. N/A R= ft2 <br /> 7. Windows Description Area . NIA R= ft2 <br /> a. U- Factor. Dbl, U =0.60 119.64 ft <br /> SHGC: SHG = 0.32 11. Ducts <br /> b. U- Factor. Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: <br /> SEER: 14 <br /> d. U- Factor. NIA fta 13. Heating systems <br /> SHGC: <br /> e. U- Factor. N/A a. Electric Heat Pump Cap: 34 kBtu/hr <br /> ft <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab-On -Grade Edge Insulation R=0.0 1531.00 ft2 a. Electric Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft2 EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.100 Total As -Built Modified Loads: 30.62 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and • 111E.ST <br /> this calculation are in compliance I the Florida Energy specifications covered by this ly � .. .° A' <br /> • <br /> Code. calculation indicates compliance f 4i`; ; 4 ' . . � , ` • c % °= _ ip <br /> s , . <br /> *MP L V with the Florida Energy Code. I t n�rr 4. :. N O <br /> PREPARED BY: S ._.L - Before construction is completed :` .r , , ; - ' : - = "° ;� <br /> DATE: this building will be inspected for <br /> IP a �' y� '�-_ CJ: <br /> compliance with Section 553.908 . } a <br /> I hereby certify that ildlng, as • .� ^, compliance Florida Statutes. "� <br /> with the Florida Energy Code. <br /> ., , C OD �� ": <br /> • <br /> OWNER/AGENT: / /�_ �, <br /> , <br /> BUILDING OFFICIAL: <br /> DATE: 11 5 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />