Laserfiche WebLink
FORM 1100A -0$ <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi - family a. Concrete Block - Int Insul, Exterior R =4.1 998.67 ft <br /> b. N/A R= ft2 <br /> 3. Number of units, if multiple family 1 c. N/A R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft') 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> b. N/A R= ft' <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor. Dbl, U =0.60 182.25 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor. N/A ft' a. Sup: Attic Ret: Attic AN: Interior Sup. R= 6, 265 ft' <br /> SHGC: 12. Cooling systems <br /> c. U- Factor. N/A ft2 a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft' 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft <br /> HSPF: 8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 EF: 0.92 <br /> b. N/A R= ft' b. Conservation features <br /> c. N/A R= ft' None <br /> 15. Credits Pstat <br /> Total As -Built Modified Loads: 33.08 PASS <br /> Glass/Floor Area: 0.133 <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and •�OFTKE Srq . <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti , O '•. <br /> . t., <br /> Code. ` calculation indicates compliance r co 47 �%-, ' <br /> 4110- with the Florida Energy Code. 1. /Nu. .,,.. ' %, 0 <br /> PREPARED B • t k " � 4 � Before construction is completed ` i •y� DATE: this building will be inspected for O - <br /> compliance with Section 553.908 t e <br /> 1 hereby certify that this budding, design as desi ' in compliance Florida Statutes. ` : " <br /> with the Florida Energy Code. / ?Ob yvE / / OWNER/AGENT: !/�a ) BUILDING OFFI IAL: /7 { <br /> DATE: ' I l i A i r : � DATE: / Z - 9 2P <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />