Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: 374 44 419/L4f.-Ly,J A.0. Permit Office: 2epk t r it; (t-S <br /> City, State, Zip: TAMPA , FL , Permit Number: 1 g <br /> Owner: LENNAR Jurisdiction: ( 1 600 <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Exterior R=4.1 998.67 ft <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c. N/A R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor: Dbl, U =0.60 182.25 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: N/A ft' a. Sup: Attic Ret: Attic AH: Interior Sup. R= 8, 285 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor: N/A ft a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U-Factor: N/A ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft2 HSPF:8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 EF: 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.133 Total As -Built Modified Loads: 33.08 PASS <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and .''' 4 TKE ST q? ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this �• �'� • <br /> Code. 1111 calculation indicates compliance : � 'v „ ��'' .'s'• <br /> C with t Florida Energy Code. 11- • Wr„ _ € .,, ; ,: � 0 <br /> PREPARED B • �� - \ = -•. .! 1 .-- Before construction is completed i r -- ti' <br /> DATE: this building <br /> will be inspected for ' 04 ` 6�° , <br /> 9 P :z, : r „�_, :a: <br /> compliance with Section 553.908 t. , `.. <br /> I hereby certify that this building, as desi• • pliance Florida Statutes. '. <br /> with the Florida Energy Code. -i `••.,C <br /> OD '?' <br /> OWNER/AGENT: <br /> � i,7 BUILDING OFFICIAL: <br /> DATE: �; DATE: / ” f -67 <br /> 1 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />