My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10321
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10321
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2011 10:56:48 AM
Creation date
1/28/2011 10:56:43 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10321
Building Department - Name
KOB PROPERTIES LLC
Address
7813 7833 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AES 7788 Series RF Subscriber Unit — Initallation and Operation Manual <br /> 1.1 Description <br /> The 7788E Subscriber Unit is an AES - IntelliNet RF Communicator, which is typically <br /> used to Zink an alarm panel to an alarm monitoring central station. This series unit is UL <br /> Listed and NFPA compliant for commercial fire alarm monitoring. This unit has 8 wired <br /> inputs. All 8 inputs are of the end of line resistor (EOL) type. For those that need or <br /> want the reversing voltage inputs, there is another model — 7744F that has four inputs of <br /> the EOL type and four reversing voltage inputs. <br /> L2 New features <br /> This section is included for those customers familiar with other AES IntelliNet UL <br /> Subscriber products. Listed below are the new features incorporated into the unit. <br /> • Normally Open Relay on board for Acknowledge Delay / Antenna Cut / Low <br /> Battery / Charger Fail output. Formally was an open collector output and only for <br /> Antenna cut / Acknowledge Delay. Relay energized for normal condition, de- <br /> energized for any fault or loss of power. <br /> • Separate power no longer required for the Zone Input Module as required on the <br /> 7750 -F -4X4 and 7750 -F -8. <br /> • AC Failure Random Reporting Delay. AC failure /restore messages are generated <br /> when they exist continuously for 100 minutes.. The actual transmission of the <br /> generated message is delayed a random number of minutes between 0 and 60 <br /> The delay is set at the time the event is generated. <br /> • Transceiver power PTC is added. It is installed in series with the power line to <br /> the transceiver disconnecting power if the transceiver draws to much current. <br /> • Remote programming using software at the central station is disabled when <br /> Trouble Packets are enabled. Trouble Packets are enabled by entering Y to "Fire <br /> Zones ? Y/N:" prompt in Zone Programming. This can temporarily be enabled <br /> using a directly attached programmer in the Programmer lack. <br /> 1.3 Easy Installation <br /> The 7788F unit is housed in a rugged lockable steel box for long lasting protection and <br /> easy installation. The alarm panel's alarm outputs are connected to the 7788E Unit. A <br /> supplied AES - IntelliNet tamper resistant 2.5 dB flexible antenna can be secured to the <br /> subscriber enclosure in the provided hole, or use a remotely installed antenna, purchased <br /> separately. Once powered and properly configured, the 7788F RF Subscriber self- enrolls <br /> into the AES - IntelliNet wireless network, receives signals from the alarm panel and <br /> transmits them via wireless mesh radio to the AES - IntelliNet central receiver. <br /> 1.4 Power Requirements <br /> The steady state DC current draw is only 15OmA (21 OmA with optional 7067 IntelliTap <br /> or 7770 FireTap Modules). The peak current draw of 1.2A (1.3A with optional 7067 or <br /> 7770) for RF power output levels of 2W, is only for a very short transmit duration of less <br /> than 1/3 second. <br /> AES Corporation s 40 -7788. Rev 3a. 4/9/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.