My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10387
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2011 8:11:53 AM
Creation date
1/31/2011 8:11:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10387
Building Department - Name
BOLENDER INVESTMENTS INC
Address
4918 AIRPORT RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 2 — Components <br /> Page 2 -3 <br /> REV. 2 <br /> MODEL ECH3 - MODEL MB -P2 - CONTROL HEAD <br /> ELECTRIC CONTROL HEAD MOUNTING BRACKET <br /> The Model ECH3 electric control head is an electrically <br /> operated control head which can be connected to the The Model MB -P2 mounting bracket must be used to mount <br /> PCI- 15/25s/35/50s/70 cylinder valve. This control head will the Model MCH3, NMCH3 or ECH3 control head if the con <br /> support an electric thermal detection system, a remote trol head is not mounted directly on a cylinder valve. See <br /> ► mechanical pull station (Model RPS -M), and an electric gas Figure 2 -7. <br /> shut -off valve. It will not support a fusible link detection sys- <br /> • tem. A micro switch (Model MS -DPDT) is included. The <br /> Model ECH3 control head is available in both 120 VAC <br /> (Model ECH3 -120) and 24 VDC (Model ECH3 -24). It is <br /> equipped with a local manual control handle that allows for <br /> mechanical system actuation. Operation of the local manual <br /> control requires removing the pull pin and rotating the han- <br /> dle clockwise. The Model ECH3 control head can actuate a 0 <br /> • maximum of five (5) cylinders with the 16 gram CO2 car- <br /> ►tr 0 <br /> idge. See Figure 2 -6. <br /> MODEL ECH3; CONTROL HEAD Q <br /> I 4 , ` �I /- PULL P �I nmu RAMIE 2 -7. Model MB -P2 — Control Head <br /> Mounting Bracket. <br /> TO RELEASE FIRE g <br /> 002846PC <br /> SUPPRESSION SYSTEM <br /> MO C*JA ► <br /> IMIN TTE 1 :47 -254: U I- CAUTION <br /> 7, Do not screw the control head directly to a wall as this <br /> ( will warp the control head, not allowing the mecha- <br /> nism to actuate. <br /> Figure 2 -6. Electric Control Head. <br /> 004789PC <br /> MODEL NMCH3 - MECHANICAL MODEL PDA -D2 PNEUMATIC <br /> CONTROL HEAD ACTUATING ADAPTOR <br /> The Model NMCH3 Mechanical Control Head is a fully The Model PDA -D2 Pneumatic Actuating Adaptor is used to <br /> mechanical control head which can be connected to the open the cylinder valve when the system is actuated. It <br /> PCI- 15/25s/35/50s/70 cylinder valve. This control head will must be installed on the valve of each cylinder unless a <br /> support a fusible link detection system, a remote mechani- control head has been mounted on the cylinder valve. See <br /> cal pull station (Model RPS -M), and a mechanical or electric Figure 2 -7a. <br /> ► shut -off valve. A micro switch (Model MS -SPDT, MS -DPDT, <br /> MS -3PDT, or MS -4PDT) can be ordered separately and field <br /> installed. There is no local manual actuation for the Model <br /> NMCH3. The Model NMCH3 control head can actuate a <br /> ..maximum of five (5) cylinders. See Figure 2 -6a <br /> WOE. f' f lc -43 :Of. ; ?O H_ rI <br /> 5 <br /> Figure 2 -7a. Model PDA -D2 <br /> Pneumatic Actuating Adaptor. <br /> _ ► 006886PC <br /> Figure 2 -6a. Mechanical Control Head. <br /> ► 006843PC <br /> ULEX 3437 CEx732 <br /> March 17, 2004 <br />
The URL can be used to link to this page
Your browser does not support the video tag.