Laserfiche WebLink
Chapter 3 — System Design <br /> • Page 3 -18 <br /> REV. 1 <br /> Step No. 5 Check to make certain minimum volumes and <br /> 10. The internal equivalent length volume of <br /> maximum volume allowed between first nozzle <br /> and last nozzle are not exceeded (Tank Chart). as part t o of the not have too considered <br /> Check each rule In "General Piping Requirements" p m O pipe volume. <br /> (Example make certain none have been exceeded. If any (Ele system OK) <br /> requirement is exceeded, change to a different 11. When utilizing different size pipe in the <br /> pipe size and recalculate. See Figure 3 -22. total system, the largest size must start <br /> Refer to Tank Chart first and the additional pipe must <br /> decrease as it approaches the nozzle. <br /> Minimum Pipe Volume for PCL -300 is 300 (Example system N /A) <br /> milliliters protecting a fryer, wok, or range 12. Elbow(s) or swivel adaptors located at <br /> (Example system pipe volume Is 1781 milliliters, <br /> therefore OK) the nozzles do not have to be counted in <br /> the 25 elbow maximum requirement. <br /> Maximum Pipe Volume for PCL -300 is 1910 (Example system OK) <br /> milliliters (Example system pipe volume is 13. Additional piping requirements when <br /> 1781 milliliters, therefore OK) <br /> Maximum Volume Allowed Between First protecting a range, wok, or a fryer: <br /> Nozzle and Last Nozzle for PCL -300 is 1125 "PCL -300 - tub a of 300 mi and four <br /> milliliters (Example system, the amount of 3/8 (4) flow numbers required in total <br /> in. piping between G and L, Is 25.5 feet. 25.5 system. Of that minimum, 239 ml and <br /> feet x 37.5 mis. /ft. = 956.3 ml, therefore, OK) two (2) flow numbers must be utilized <br /> at or before the range, wok, or fryer. <br /> Refer to General Piping Requirements (Example system has 1781 ml and 10 <br /> 1. Spilt piping and straight piping are both flow numbers, therefore, OK. The exam - <br /> allowed on PCL -300 and PCL -460 pie system has mi and 3 flows <br /> including the fryerer, , therefore, OK) <br /> systems. (Example system OK) <br /> 2. PCL -600 systems must use split piping 'PCL 460 — Minimum of 660 ml and tan <br /> only, with no nozzle located before the (10) flow numbers required in total <br /> split, and with a maximum of 14 flow system. Of that minimum, 180 ml and <br /> two (2) flow numbers must be utilized at <br /> points per side. 1/2 in. minimum piping or before the range, wok, or fryer. <br /> must be used up to the first split. <br /> (Example system N /A) •PCL -600 — Minimum of 960 ml and four <br /> 3. Maximum volume for 1/4 in. pipe teen (14) flow numbers required in total <br /> between a nozzle and the preceding tee system. Of that minimum, 120 ml and 2 <br /> is 410 mis. (Example system N /A) flow numbers must be utilized at or <br /> before the range, wok, or fryer. <br /> 4. Maximum flow numbers for 1/4 in. pipe <br /> is 6. (Example system N /A) <br /> 5. Maximum number of elbows between a RUN. PIPING <br /> RULE NO. 1, 8, B <br /> nozzle and the preceding tee is 5. GEN. PIPING <br /> (Example system has a maximum number TANK CHART t , 4 001/ RULE NO. 5 <br /> of 2, therefore, OK) P IPE VOLPE V L MAXIMUM <br /> PIPE <br /> TANK CHART <br /> 6. Maximum of 25 elbows are allowed in MAX. VOL <br /> GEN. <br /> the total piping system. (Example system PIP NG \ �♦ BETWEEN <br /> _ FIRST AND <br /> has 11 elbows, therefore, OK) RULE LAST NOZZLE <br /> NO. 10 TANK CHART ` <br /> 7. Maximum difference In elevation between GEN. PIPING <br /> MAX. V OL. RULE NO. 12 <br /> the tank outlet and any nozzle, or the tank GEN. BETWEEN FIRST <br /> outlet and the highest or lowest horizontal <br /> PIPING AND L4STNOZZL ° <br /> RULE <br /> pipe run, is 10 ft. (3.1 m) (Example system <br /> NO. 7 GEN. PIPING V0 0 <br /> has 5' -6" (1.7 m), therefore, OK) RULE NO.5 t ° <br /> 8. No traps are allowed in the piping <br /> network. (Example system has no traps, GEN. PIPING 008197PC <br /> p <br /> therefore, OK) RULE N0.13 <br /> 9. Pipe lengths are measured from center to <br /> center of fittings. (Example system pipe Figure 3 - 22. <br /> lengths were measured from center to center <br /> of fittings, therefore, OK) <br /> ULEX 3830 <br /> April 1, 2004 PN551274(2) <br />