ADVANCED AUTO PARTS
Building Department - Doc Type
Permit
Permit #
10-10589
Building Department - Name
ADVANCED AUTO PARTS
Address
5637 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fastening #12: Min. 2,500 psi Concrete Deck Only: OMG #15 Large Head Roofgrip with <br /> Polymer Batten Strip. Screws are spaced at maximum 12 in (305 mm) o.c. within <br /> the minimum 4.5 in (114 mm) wide laps, which are spaced at maximum 144 in <br /> (3658 mm) o.c. and sealed with a minimum 1.25 in (32 mm) wide heat weld <br /> placed on each side of the batten strip. <br /> Maximum Design Pressure: -45 psf <br /> Fastening #13: Min. 2,500 psi Concrete Deck Only. OMG #15 Large Head Roofgrip with <br /> Polymer Batten Strip. Screws are spaced at maximum 6 in (152 mm) o.c. within <br /> the minimum 5 in (127 mm) wide laps, which are spaced at maximum 144 in <br /> (3,658 mm) o.c. and sealed with a minimum 1.5 in (40 mm) wide heat weld <br /> placed on the outside edge of the batten strip. <br /> Maximum Design Pressure: -60 psf <br /> Fastening #14: Approved Lightweight concrete Deck cast over Steel or Concrete Only: <br /> Fasteners installed through lightweight concrete to steel deck. JM TPO <br /> membrane secured with OMG #15 Large Head Roofgrip spaced max 6" o.c. <br /> through the Polymer Batten Strip. The batten strip and fasteners are placed within <br /> the min. 4.5" wide laps are spaced at max 143.5" o.c. and sealed with a min 0.75" <br /> wide heat weld on the inside of the lap and a min. 1" wide heat weld on the <br /> outside of the lap. Maximum Design Pressure: -90 psf <br /> Fastening #15: Cementitious wood Fiber or Poured Gypsum Deck Only: N.T.B Magnum <br /> Fasteners with 2 in (51 mm) head spaced at max 6 in (1152 mm) o.c. within the <br /> minimum 4.5 in (114 mm) wide laps, which are spaced at max 57 in (1448 mm) <br /> o.c. and sealed with a minimum 1.5 in (38 mm) heat weld. Fasteners shall have <br /> minimum 2 in (51 mm) embedment. <br /> Maximum Design Pressure: -45 psf. <br /> Maximum Design <br /> Pressure: See Fastening Options for Specific Deck Type <br /> NOA No.: 07- 0517.06 <br /> Expiration Date: 07/17/12 <br /> Approval Date: 07/12/07 <br /> �-- Page 22of30 <br />