Laserfiche WebLink
83040.02- 501-44 <br /> Architectural Testing Page 6of <br /> Test Results: The temperature during testing was 20.5 °C (69 °F). The results are tabulated <br /> as follows: <br /> Paragraph Title of Test - Test Method Results AIlowed <br /> Test Specimen #1: SD-R35 1797 x 2019 (71 x 80) <br /> 5.3.1 Operating Force per ASTM E 2068 ** <br /> Initiate motion 90 N (20 lbf) I35 N (30 lbf) <br /> Maintain motion 45 N (10 Ibf) 90 N (20 lbf) <br /> Locks 27 N (6 lbf) 100 N (22.5 lbf) <br /> 5.3.2.1 Air Leakage Resistance per ASTM E 283 ** <br /> 75 Pa (1.6 pst) 1.11 Llsfm 1.5 L/s/m <br /> (0.22 cfmfft (03 cfmlft max. <br /> Note #1: The tested specimen meets (or exceeds) the performance levels specified in <br /> AAMAJWDJtf4JcSA 101/I.S2/A$40 -O5 for air leakage resistance. <br /> 5.3.3.2 Water Penetration Resistance per ASTM E 547 ** See Note #2 <br /> 5.3.4.2 Uniform Load Deflection per ASTM E 330 ** See Note #2 <br /> 5.3.4.3 Uniform Load Structural per ASTM E 330 ** See Note 112 <br /> Note 0: The client opted to start at a pressure higher than the rninirmun required. Those <br /> results are listed under "Optional Pet forrance" <br /> 53.5 Forced Entry Resistance per ASTM F 842 ** <br /> Type: A Grade: 10 <br /> Disassembly Test No entry No entry <br /> Tests Al through A6 No entry No entry <br /> Panel Manipulation Test No entry No entry <br /> Lock Hardware Manipulation Test No entry No entry <br /> 5.3.6.2 Thermoplastic Corner Weld Test ** Meets as stated Meets as stated <br /> Note: Reference Architectural Testing, Inc. Report No. 83040.01- 501 -44, dated 05/28/08 <br /> for these test results (* *). <br />