My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9292
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9292
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2011 4:01:17 PM
Creation date
3/21/2011 3:51:40 PM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
09-9292
Building Department - Name
CITY OF ZEPHYRHILLS
Address
6907 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 10 TFP171 <br /> SPRINKLER FINISH <br /> K TYPE NATURAL CHROME WHITE LEAD <br /> BRASS PLATED POLYESTER COATED <br /> PENDENT (TY3231) <br /> and <br /> 2 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A <br /> 1/2" RECESSED PENDENT <br /> NPT (TY323) <br /> PENDENT (TY4231) <br /> and <br /> 4 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A <br /> 3/4" RECESSED PENDENT <br /> NPT (TY4231) <br /> PENDENT (TY3231) <br /> and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) <br /> 5.6 UPRIGHT (TY3131) OR <br /> 1/2" RECESSED PENDENT 175 PSI (12,1 BAR) <br /> NPT <br /> (TY323) (SEE NOTE 1) N/A <br /> PENDENT (TY4231) <br /> and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) <br /> 8 UPRIGHT (TY4131) <br /> 3/4" RECESSED PENDENT <br /> NPT (TY4231) N/A <br /> NOTES: <br /> 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by <br /> Underwriters Laboratories, Inc. for use in Canada (C -UL); and , the Approval by the City of New York. <br /> TABLE C, MAXIMUM WORKING PRESSURE <br /> nections. Higher levels of torque may The Series TY -FRB Recessed Pen - <br /> Installation distort the sprinkler inlet and cause dent Sprinklers must be installed in <br /> leakage or impairment of the sprinkler. accordance with the following instruc- <br /> The Series TY -FRB Sprinklers must tions. <br /> be installed in accordance with the fol- Do not attempt to make -up for insuffi- <br /> lowing instructions: cient adjustment in the escutcheon Step A. After installing the Style 10. <br /> plate by under- or over - tightening the 20, 30, or 40 Mounting Plate, as appli- <br /> NOTES sprinkler. Readjust the position of the cable, over the sprinkler threads and <br /> Do not install any bulb type sprinkler if sprinkler fitting to suit. with pipe thread sealant applied to the <br /> pipe threads hand <br /> li hten <br /> quid from the bulb. With the sprinkler The Series TY -FRB Pendent and Up- klerr i nto the sprinkler lfitting. the sprin <br /> q P right Sprinklers must be installed in <br /> held horizontally, a small air bubble accordance with the following instruc- Step B. Tighten the sprinkler into the <br /> should be present. The diameter of the tions. sprinkler fitting using only the W -Type <br /> air bubble is approximately 1/16 inch 7 Recessed Sprinkler Wrench (Ref. <br /> for the 135F/57°C to 3/32 Step 1. Pendent sprinklers are to be <br /> ( 1,6 mm) 286°F/141°C installed in the pendent position, and Figure 14). the W-Type to Figure <br /> inch (2,4 mm) for the 286 °F /141 C p p 2, 3, and 4, the W -Type 7 Recessed <br /> temperature ratings. upright sprinklers are to be installed in Sprinkler Wrench is to be applied to <br /> the upright position. the sprinkler wrench flats. <br /> A leak tight 1/2 inch NPTsprinklerjoint Step 2. W ith pipe thread sealant a p <br /> should be obtained with a torque of 7 p p i p p Step C. After the ceiling has been in- <br /> to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- plied to the pipe threads, hand tighten stalled or the finish coat has been ap- <br /> mum of21 ft. lbs. (28,5 Nm) of torque the sprinkler into the sprinkler fitting. plied, slide on the Style 10, 20, 30, or <br /> may be used to install sprinklers with Step 3. Tighten the sprinkler into the 40 Closure over the Series TY -FRB <br /> 1/2 NPT connections. A leak tight 3/4 sprinkler fitting using only the W -Type Sprinkler and push the Closure over <br /> inch NPT sprinkler joint should be ob- 6 Sprinkler Wrench (Ref. Figure 13). the Mounting Plate until its flange <br /> tained with a torque of 10 to 20 ft.lbs. With reference to Figures 1, 2, 3, and comes in contact with the ceiling. <br /> (13,4 to 26,8 Nm). A maximum of 30 4, the W -Type 6 Sprinkler Wrench is to <br /> ft .lbs.(40,7Nm)oftorqueistobeused be applied to the sprinkler wrench <br /> to install sprinklers with 3/4 NPT con- flats. <br />
The URL can be used to link to this page
Your browser does not support the video tag.