TFP171 Page 7 of 10 <br /> 2 -7/8" DIA. 2 -7/8" DIA. <br /> (73,0 mm) 3/4" (19,1 mm) (73,0 mm) <br /> 5/8±1/4" <br /> 1/211/8" 1/2" (12,7 mm) <br /> (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) <br /> FACE OF (57,2 mm) 1 MOUNTING FACE OF (57,2 mm) MOUNTING <br /> SPRINKLER I PLATE SPRINKLER PLATE <br /> FITTING FITTING <br /> 1/8" 1/8" <br /> 1; (3,2 mm) 1 m (3,2 mm) 111 <br /> I- ii j MOUNTING t <br /> MOUNTING <br /> �: 1 SURFACE �' <br /> SURFACE iii ���� ii •�ks, <br /> CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1 -5/16" (33,3 mm) <br /> TY -FRB 13/16" (20,6 mm) TY-FRB 1 -1/16" (27,0 mm) <br /> FIGURE 5 FIGURE 6 <br /> SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT <br /> WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT <br /> STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON <br /> 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT <br /> 2 -7/8" DIA. 2 -7/8" DIA. <br /> 5/811/4" (73,0 mm) 314" (19,1 mm) (73,0 mm) <br /> 1/211/8" 1/2" (12,7 mm) <br /> (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) <br /> FACE OF (57,2 mm) 1 MOUNTING FACE OF (57,2 mm) <br /> I MOUNTING <br /> SPRINKLER <br /> PLATE SPRINKLER PLATE <br /> FITTING FITTING <br /> 1/8" 1/8" <br /> •!' (3,2 mm) •� (3,2 mm) <br /> Jill a , <br /> lalil, , ��l�ll, ��' <br /> mil r , <br /> 111 w <br /> MOUNTING IN <br /> �r <br /> MOUNTING SURFACE � ■ <br /> SURFACE -• -- .- .. <br /> CLOSURE SERIES 1 -1/4" (31,8 mm) , CLOSURE SERIES 1 -1/4" (31,8 mm) <br /> TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) <br /> FIGURE 7 FIGURE 8 <br /> SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT <br /> WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT <br /> STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON <br /> 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT <br /> Care and objects; otherwise, non - operation in by brushing it with a soft bristle brush. <br /> the eventofa fire or inadvertent opera- <br /> Care must be exercised to avoid dam <br /> M aintenance tion may result age to the sprinklers - before, during, <br /> Absence of an escutcheon, which is and after installation. Sprinklers dam - <br /> The Series TY -FRB Sprinklers must used to cover a clearance hole, may aged by dropping, striking, wrench <br /> be maintained and serviced in accord delay the time to sprinkler operation in twist/slippage, or the like, must be re- <br /> ance with the following instructions: a fire situation. placed. Also, replace any sprinkler <br /> Sprinklers that are found to be leaking that has a cracked bulb or that has lost <br /> NOTES or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation <br /> • <br /> Before closing a fire protection system must be replaced. Section). . <br /> main control valve for maintenance never must i ne r <br /> tic sprinklers rnklers mus be Frequent visual inspections are rec- <br /> work on the fire protection system that Automatic plated, coated s ne err ommended to be initially performed for <br /> it controls, permission to shutdown the p p otherwise corrosion resistant coated sprinklers, <br /> affected fire protection system must be altered after leaving the factory. Modi- after the installation has been com- <br /> obtained from the proper authorities fied sprinklers must be replaced. pleted, to verify the integrity of the cor- <br /> and all personnel who maybe affected Sprinklers that have been exposed to rosion resistant coating. Thereafter, <br /> by this action must be notified. corrosive products of combustion, but annual inspections per NFPA 25 <br /> have not operated, should be replaced should suffice; however, instead of in- <br /> The owner must assure that the sprin- if they cannot be completely cleaned <br /> specting from the floor level, a random <br /> klers are not used for hanging of any by wiping the sprinkler with a cloth or <br />