09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN -7101 • A1-110 <br /> FireWarden- 100 -2(E) <br /> 1 telli ent Addressable FACP N OT I F I E R <br /> with Built -In Communciator by Honeywell <br /> Addressable <br /> GENERAL <br /> The Notifier FireWarden -100 -2 (NFW2 -100) is a combination <br /> FACP (Fire Alarm Control Panel) and DACT (Digital Alarm <br /> Communicator/Transmitter) all on one circuit board. This com- <br /> pact intelligent addressable control panel has an extensive list <br /> of powerful features. <br /> The SLC (Signaling Line Circuit) of the FireWarden -100 -2 <br /> operates using a Rapid Group Polling communication protocol <br /> technology that polls multiple devices simultaneously for a <br /> quicker device response time.This patented technology allows <br /> a fully - loaded panel with up to 198 devices to report an inci- <br /> dent and activate the notification circuits in under 10 seconds. <br /> With this improved polling, devices can be wired on standard <br /> twisted, unshielded wire up to a distance of 10,000 feet. <br /> (Consult the wire table on page 3 for specific installation <br /> instructions.) <br /> The FireWarden - 100 -2's quick- remove chassis protects the <br /> electronics during construction. The backbox can be installed <br /> allowing field wiring to be pulled. When construction is com- <br /> pleted, the electronics can be quickly installed with just two <br /> bolts. <br /> Available accessories include LED, graphic and LCD annunci- <br /> ators, and reverse polarity /city box transmitter. <br /> The panel is programmed through the FACP's keypad or via a <br /> standard PS -2 computer keyboard, which can be plugged <br /> directly into the printed circuit board. This permits easy typing <br /> of address labels and other programming information. • PAS (Positive Alarm Sequence) and presignal delay per <br /> NOTE: Unless otherwise specified, the terms FireWarden -100 -2 is point (NFPA 72 compliant). <br /> used in this document to refer to both the FireWarden -100 -2 and NOTE: Only detectors may participate in PAS. <br /> the FireWarden - 100 -2E FACPs (Fire Alarm Control Panels). SLC LOOP: <br /> FEATURES • SLC can be configured for NFPA Style 4, 6, or 7 operation. <br /> • On board DACT. • SLC supports up to 198 addressable devices per loop (99 <br /> • Four Class B or two Class A NAC circuits. detectors and 99 monitor, control, or relay modules). <br /> • SLC loop maximum length 10,000 ft. (3,000 m.). <br /> • Selectable strobe synchronization for System Sensor, See wire table on page 3. <br /> Wheelock, and Gentex devices. <br /> • Complies with UL 864 9th Edition requirements. NOTIFICATION APPLIANCE CIRCUITS (NACS): <br /> • Remote Acknowledge, Silence, Reset and Drill via address- • Four onboard NACs with additional NAC capability using <br /> able monitor modules. output control modules (NC -100). <br /> • Up to 32 annunciators or remote annunciators via EIA- • Silence Inhibit and Auto Silence timer options. <br /> 485. • Continuous, March Time, Temporal or California code for <br /> • EIA -232 printer /PC interface (variable baud rate) on main main circuit board NACs with two -stage capability. <br /> circuit board. • Selectable strobe synchronization per NAC. <br /> • Integral 80- character LCD display with backlighting. • 2.5 amps maximum per each NAC circuit. <br /> • Real -time clock/calendar with automatic daylight savings NOTE: Maximum or total 24VDC system power shared between <br /> control. all NAC circuits and auxiliary power outputs is 3.6 amps. (System <br /> • Detector sensitivity test capability (NFPA 72 compliant). power increases to 6.6 amps with optional XRM - 24 transformer.) <br /> • History file with 1,000 -event capacity. PROGRAMMING AND SOFTWARE: <br /> • Maintenance alert warns when smoke detector dust accu- • Autoprogram (learn mode) reduces installation time. <br /> mulation is excessive. <br /> • Automatic device type code verification. • Custom English labels (per point) may be manually entered <br /> or selected from an internal library file. <br /> • One person audible or silent walk test with walk -test log and • Two programmable Form -C relay outputs. <br /> printout. 99 software zones. <br /> • • Point trouble identification. <br /> • Waterflow (nonsilenceable) selection per monitor point. • Continuous fire protection during online programming at the <br /> front panel. <br /> • System alarm verification selection per detector point. • Program Check automatically catches common errors not <br /> linked to any zone or input point. <br /> DN -7101 • 06/02/06 — Page 1 of 4 <br />