My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br /> SYSTEM CAPACITY 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring <br /> • Intelligent Signalling Line Circuits 1 (TR -CEB): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. <br /> • Addressable device capacity 198 SHIPPING SPECIFICATIONS <br /> • Programmable software zones 99 <br /> • Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) <br /> high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. <br /> ELECTRICAL SPECIFICATIONS TEMPERATURE AND HUMIDITY <br /> AC Power: FireWarden - 100 -2: 120 VAC, 60 Hz, 3.0 amps. RANGES <br /> FireWarden- 100 -2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: <br /> minimum 14 AWG (2.00 mm with 600 V insulation. This system meets NFPA requirements for operation at 0 -49° <br /> Battery: Two 12 V 18AH lead -acid batteries. Battery charger C/32 -120° F and at a relative humidity 93% ± 2% RH (noncon- <br /> capacity: 7 — 18 AH. FireWarden -100 -2 cabinet holds maxi- densing) at 32°C ± 2 °C (90 °F ± 3 °F). However, the useful life <br /> mum of two 18 AH batteries. of the system's standby batteries and the electronic compo- <br /> Communication Loop: Supervised and power- limited. nents may be adversely affected by extreme temperature <br /> Notification Appliance Circuits: Each terminal block pro- ranges and humidity. Therefore, it is recommended that this <br /> vides connections for two Style Y (Class B) or one Style Z system and its peripherals be installed in an environment with <br /> (Class A) for a total of four Style Y (Class B) or two Style Z a normal room temperature of 15 -27° C /60 -80° F. <br /> (Class A) NACs. Maximum signaling current per circuit: 2.5 <br /> amps. End -of -Line Resistor: 4.7K ohm, 1/2 watt (P /N 71252 NFPA STANDARDS <br /> UL listed) for Style Y (Class B) NAC. Refer to Notifier Device <br /> Compatibility Document for listed compatible devices. The FireWarden -100 -2 complies with the following NFPA 72 <br /> Two Programmable Relays and One Fixed Trouble Relay: Fire Alarm Systems requirements: <br /> Contact rating: 2.0 amps © 30 VDC (resistive), 0.5 amps © 30 — LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> VAC (resistive). Form -C relays. Supervisory). <br /> Special Application Power (24 VDC Nominal): Jumper — AUXILIARY (Automatic, Manual and Waterflow) (requires <br /> selectable (JP4) for conversion to resettable power output. Up 4XTMF). <br /> to 0.5 amps total DC current available from each output. — REMOTE STATION (Automatic, Manual and Waterflow) <br /> Power - limited. (requires 4XTMF). <br /> Four -Wire Resettable Special Application Smoke Detector — PROPRIETARY (Automatic, Manual and Waterflow). <br /> Power (24 VDC nominal): Up to 0.5 amps for powering four- — CENTRAL STATION (Automatic, Manual and Waterflow, <br /> wire smoke detectors. Power - limited. Refer to Notifier Device and Sprinkler Supervised). <br /> Compatibility Document for listed compatible devices. <br /> — AUTO DETECTOR SELF TEST <br /> Remote Sync Output: Remote power supply synchronization <br /> output. Nominal special application power: 24 VDC. Maximum AGENCY LISTINGS AND APPROVALS <br /> current: 40 mA. End -of -Line Resistor: 4.7K ohm. Output linked <br /> to NAC 1 control. Supervised and power - limited. The listings and approvals below apply to the basic FireWar- <br /> Telephone Interface: Requires dedicated business tele- den -100 -2 control panel. In some cases, certain modules may <br /> phone number with a minimum of 7 volts DC. Obtain dedicated not be listed by certain approval agencies, or listing may be in <br /> phone line directly from your local phone company. Do not use process. Consult factory for latest listing status. <br /> shared phone lines or PBX (digital) type phone line extensions. • UL: S624 <br /> CABINET SPECIFICATIONS <br /> Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x <br /> 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x <br /> Microsoft® and Windows® are registered trademarks of the Microsoft Corpo- <br /> ration. <br /> 02006 by Honeywell International Inc. All rights reserved. Unauthorized use <br /> of this document is strictly prohibited. <br /> ISO 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up -to -date and accurate. ;: •••■••• '' <br /> E R T I F I E D We cannot cover all specific applications or anticipate all requirements. <br /> ENIMEMIM 6IMMIMMEYNi All specifications are subject to change without notice. <br /> IUALITY SYSTEMS <br /> Made in the U.S. A. <br /> For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. <br /> www.notifier.com <br /> Page 4 of 4 — DN -7101 • 06/02/06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.