My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS <br /> ND -100 ND -100R contact ratings <br /> Operating voltage range: 15 to 30 VDC. Alarm auxiliary contacts* (DPDT): <br /> Standby current: 300 pA @ 24 VDC (one communication • 10 A @ 30 VDC. <br /> every 5 seconds with LED blink enabled). • 10 A @ 277 VAC (0.75 power factor). <br /> Operating temperature range: 32° to 131°F (0° to 55 °C). • 240 VA @ 249 VAC (0.4 power factor). <br /> Operating humidity range: 10% to 93% relative humidity (non- • 1/8 HP @ 120 VAC. <br /> condensing). • 1/4 HP @ 240 VAC. <br /> Storage temperature range: -22 °F to +158 °F ( -30 °C to Supervisory contact (SPST): <br /> +70 °C). <br /> • 2.0 A @ 30 VDC (resistive). <br /> Duct air velocity: 100 to 4,000 feet/min (0.5 to 20.32 m /s). "Minimum switching current for auxiliary contact must be 100 mA <br /> Shipping weight: 3.35 lbs. (1.5 kg). DC minimum @ 5 VDC. <br /> Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x ND - 100R accessory current loads <br /> 2.75" (7 cm) deep. 24 VDC <br /> ND -100 accessory current loads PA400: refer to PA400 data sheet DN - 2405. <br /> a 24 VDC RA400Z: 0 mA standby, 12 mA maximum in alarm. <br /> PA400: refer to PA400 data sheet DN - 2405. RTS451 and RTS451 KEY: 0 mA standby, 10 mA maximum <br /> RA400Z: 0 mA standby, 10 mA maximum in alarm. in alarm. <br /> RTS451 and RTS451 KEY: 0 mA standby, 7.5 mA maximum See table below for ND - 1008 current requirements. <br /> in alarm. PRODUCT LINE INFORMATION <br /> ND - 100R ND -100 Addressable low -flow duct detector housing <br /> Operating voltage range: 20 to 30 VDC, 24 VACNDC, 120/ with photoelectric smoke detector. <br /> 240 VAC auxiliary power (requires a separate auxiliary source). <br /> ND-100R Addressable low -flow duct detector housing <br /> Standby current: 300 pA @ 24 VDC (one communication with photoelectric smoke detector with DPDT <br /> every 5 seconds with LED blink enabled). relay. <br /> Operating temperature range: 32° to 131 °F (0° to 55 °C). A5053FL Replacement photoelectric sensor board. <br /> Operating humidity range: 10% to 93% relative humidity (non- A5067 Replacement power board (without relay). <br /> condensing). <br /> Storage temperature range: -22°F to +158 °F ( -30 °C to A5060 Replacement power board (with relay). <br /> +70 °C). ST -1.5 Metal sampling tube, duct widths 1' to 2' (see <br /> Duct air velocity: 100 to 4,000 feet/min (0.5 to 20.32 m /s). table on page 3 for metric lengths). <br /> Shipping weight: 3.90 lbs. (1.8 kg). ST -3 Metal sampling tube, duct widths 2' to 4'. <br /> Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x ST -5 Metal sampling tube, duct widths 4' to 8'. <br /> 2.75" (7 cm) deep. ST -10 Metal sampling tube, duct widths 8' to 12'. <br /> RA400Z Remote annunciator alarm LED. <br /> RTS451 Remote test station. Mounts in single -gang <br /> box. Includes red alarm LED and magnet test <br /> switch. <br /> RTS451 KEY Key- activated remote test station. <br /> • F36 -09 -11 Replacement filters. <br /> a <br /> � MO2 -04 -00 Replacement test magnet. <br /> -- eccen <br /> \ <br /> P SOS 48 -61 39 -00 01 ReplacemenReplacement t photo end cap for plastic sampling <br /> tube. <br /> Mr <br /> P48 -21 -00 Replacement end cap ins for t s metal . sampling <br /> .. tube. <br /> t T80 -71 -00 Replacement sampling tube. <br /> RA400Z RTS451 RTS451KEY <br /> 7OO6cr II Ibl <br /> ND -100R current requirements (using no accessories) <br /> Power supply voltage 20 - 30 VDC 24 VAC, 120 VAC, 220/240 VAC, <br /> 50/'60 Hz 50/60 Hz 50/60 Hz <br /> Max. standby current 26 mA 65 mA RMS 44 mA RMS 25 mA RMS <br /> Max. alarm current 87 mA 182 mA RMS 52 mA RMS 30 mA RMS <br /> Alarm response time 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. <br /> Power -up time 2 sec. 2 sec. 2 sec. 2 sec. <br /> Page 2 of 4 -- DN -7006 • 05/09/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.