My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 9, 2005 DN -7006 • A1-340 <br /> N OT I F I E R® ND -100 and ND -100R <br /> Low -Flow Photoelectric Duct Smoke <br /> by Honeywell Detectors for FireWarden -100 <br /> Section: Addressable <br /> GENERAL � California <br /> /. , . State Fire <br /> ND -100 and ND100R photoelectric duct smoke detectors are Marshal <br /> M EA • 4 7 <br /> used exclusively with the NOTIFIER FlreWarden -100 (NFW- ® 320 02 E Vol. II 3240 0028:232 <br /> 100) addressable control panel. They provide low -flow tech- <br /> (ND (ND - 100R) <br /> nology that enables duct smoke detection throughout a broad LISTED 3240 - 0028:236 <br /> range of airflow environments in HVAC applications. The low- S635 (ND - 100) <br /> flow technology can detect smoke at air speed velocities of MARYLAND <br /> 100 feet per minute (0.5 m /sec) or greater, while continuing State Fire Marshal <br /> the same reliable performance to 4,000 feet per minute (20.32 Permit # 2173 (ND <br /> m /sec). The intelligent low -flow duct detectors sample air cur- <br /> rents passing through a duct and gives dependable perfor- <br /> mance for shutdown of fans, blowers, and air conditioning <br /> systems, preventing the spread of toxic smoke an fire gases <br /> through the protected area. <br /> ND -100 and ND -100R provide a remote alarm output for use <br /> with auxiliary devices, such as the RA400 remote LED annun- <br /> ciator, as well as remote test capability with the RTS451 or ND - 100 <br /> RTS451 KEY Remote Test Stations. The ND -100R features a <br /> Form -C relay. <br /> APPLICATIONS " ' <br /> Duct smoke detectors have specific limitations, they are: <br /> • NOT a substitute for open area smoke detectors. <br /> • NOT a substitute for early warning detection. <br /> • NOT a replacement for a building's regular fire detection <br /> system. <br /> Please call NOTIFIER for a copy of System Sensor's applica- <br /> tion guide, Proper Use of Smoke Detectors in Duct Applica- <br /> tions, (A05- 1004 -00). <br /> FEATURES <br /> • Air velocity rating from 100 to 4,000 feet per minute (0.5 to <br /> 20.32 m/sec). <br /> • Patented telescopic sampling tube. -� <br /> • Easily accessible code wheels for addressing detector. ND - 100R `� "; <br /> • Outside mounting tabs. • �. <br /> • Mounts to round or rectangular ducts from 1' to 12' (0.3 to 3.7� <br /> meters) wide. <br /> • Transparent cover for convenient visual inspection. <br /> • Powered outputs for remote LED, and remote test and "~ <br /> sounder. <br /> • Two Form - C auxiliary contacts (ND 100R). <br /> • Patented cover - tamper trouble signal. The duct smoke detector terminals accommodate wire sizes <br /> • ND -100R requires both com line power and one of the up to 12 AWG (3.1 mm Flexible conduit is recommended for <br /> following: 24 VACNDC or 120/220 VAC for operation. the last foot (30.48 cm) of conduit; solid conduit connections <br /> INSTALLATION may be used if desired. <br /> Refer to installation manuals for control panel and duct Smoke detectors and alarm system control panels have speci- <br /> detector for detailed information or to install equipment. control for l Signaling Li Circuit ring requirements wui nt ssb the <br /> control panel specifications for wiring requirements bee fore <br /> Wiring: For signal wiring (the wiring between detectors or wiring the detector loop. The ND -100 and ND -100R detectors <br /> from detectors to auxiliary devices), it is recommended that are designed for ease of wiring; their housing provides a ter - <br /> single conductor wire be no smaller than 18 AWG (0.78 mm minal strip with clamping plates. <br /> This document is not intended be used for W installation purposes. We try to keep our 1S0 900 <br /> prrod duct ct information up -to -to -date te and accurate. We cannnot ot cover ver all ll specific applications or <br /> anticipate all requirements. All specifications are subject to change without notice. <br /> For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 c E Ft T 1 F Ii E ID <br /> N OTI FI ER' ENWIwEENNI i MNNEIICIIRIN6 <br /> by Honeywell 12 Clintonville Road, Northtord, Connecticut 06472 QUALITY S Y S T E M S <br /> DN -7006 • 05/09/05 — Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.