Laserfiche WebLink
June 15, 2005 DN -6999 • A1-350 <br /> 8 N OT 1 F 1 E R `R' Addressable Monitor Modules <br /> for the FireWarden -100: <br /> by Honeywell NMM -100, NMM -100P, NZM -100, NDM -100 <br /> Section: Addressable <br /> GENERAL <br /> - California <br /> Four different monitor modules are available for \ State Fire <br /> NOTIFIER's FireWarden -100 intelligent fire alarm control M EA ( ) Marshal <br /> panels to suit a variety of applications. Monitor modules .. vol 7300- 0028 :230 <br /> are used to supervise a circuit of dry- contact in ut de 72-01-E Vol. II <br /> p (except NDM - 100) '" (except NDM - 100) <br /> vices, such as conventional heat detectors and pull sta- LISTED <br /> tions, or monitor and power a circuit of two -wire smoke S635 <br /> detectors (NZM 100). <br /> NMM -100 — The NMM -100 Monitor Module is a standard - <br /> sized module (typically mounts to a 4.0" [10.16 cm] square APPROVED <br /> box) that supervises either a Class A (Style D) or Class B <br /> (Style B) circuit of dry- contact input devices. <br /> NMM -100P — The NMM -100P is a Miniature Monitor Mod- , n n ■ <br /> ule (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" C ,--„,\ (1.270 cm) D) used to supervise a Class B (Style B) cir- 0 1 1 <br /> cuit. Its compact design allows the NMM -100P to be O <br /> mounted in a single -gang box behind the device it is moni- <br /> toring. ®9 6 0 L,I <br /> NZM -100 — The NZM -100 Interface Module is a stan- ® 8 3 s � .. �i 1 ® i <br /> dard -sized module used to monitor and supervise com- 2 13 <br /> patible two -wire, 24 volt, smoke detectors on a Class A ® 7 TE s so isg 2 ® ` <br /> (Style D) or Class B (Style B) circuit. 6 A 3 <br /> NDM -100 — The NDM -100 Dual Monitor Module is a stan- <br /> ®5 z��y' 4 ® o <br /> dard -sized module (typically mounts to a 4.0" [10.16 cm] ONES ° <br /> square box) that supervises two Class B (Style 8) circuits LOOP ADDRESS <br /> of dry- contact input devices. ( \ /2 <br /> c n <br /> NMM -100 MONITOR MODULE ` 0 <br /> • Built -in type identification automatically identifies this de- U U <br /> vice as a monitor module to the control panel. <br /> • Powered directly by two -wire SLC loop. No additional NMM -100 and NZM -100 <br /> power required. <br /> • High noise (EMF /RFI) immunity. quired for supervision of the Style D circuit. Maximum IDC <br /> • SEMS screws with clamping plates for ease of wiring. resistance is 1,500 ohms. <br /> • Direct Decade 01 – 99 (FireWarden -100) entry of ad- NMM - 100 Operation — Each NMM -100 uses one of <br /> dress. 99 (FireWarden -100) available module addresses on an <br /> • LED flashes red during normal operation and latches SLC loop. It responds to regular polls from the control <br /> on steady to indicate alarm. panel and reports its type and the status (open /normal/ <br /> The NMM -100 Monitor Module is intended for use in intel- short) of its Initiating Device Circuit (IDC). A flashing LED <br /> ligent, two -wire systems, where the individual address of indicates that the module is in communication with the con - <br /> each module is selected using the built -in rotary switches. trol panel. The LED latches steady on alarm (subject to <br /> It provides either a two -wire or four -wire Class A or Class current limitations on the loop). <br /> B fault - tolerant Initiating Device Circuit (IDC) for normally- NMM -100 Specifications <br /> open- contact fire alarm and supervisory devices. Nominal operating voltage: 15 to 32 VDC. <br /> NMM -100 Applications — Use to monitor a zone of Maximum current draw: 5.1 mA (LED on). <br /> four -wire smoke detectors, manual fire alarm pull stations, Average operat current: 400 pA (LED flashing). <br /> waterflow devices, or other normally -open dry- contact <br /> alarm activation devices. May also be used to monitor EOL resistance: 47K ohms. <br /> normally -open supervisory devices with special supervi- Temperature range: 32 °F to 120 °F (0 °C to 49 °C). <br /> sory indication at the control panel. Monitored circuit may Humidity range: 10% to 93% noncondensing. <br /> be wired as an NFPA Style B (Class B) or Style D (Class D) Dimensions: 4.5" (11.43 cm) high x 4.0" (10.16 cm) wide x <br /> Initiating Device Circuit. A 47K ohm End -of -Line Resistor 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square <br /> (provided) terminates the Style B circuit. No resistor is re- x 2.125" (5.398 cm) deep box. <br /> This document is not intended to be used for installation purposes. We try to keep our ISO 9001 <br /> product information up -to -date and accurate. We cannot cover all specific applications <br /> or anticipate all requirements. All specifications are subject to change without notice. <br /> For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 C E Ft T 1 F I E ID <br /> 0 <br /> NOTI FI ER' lI01MWr IMNNRC1UIIri <br /> by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS <br /> DN -6999 • 06/15/05 — Page 1 of 3 <br />