My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NMM -100P MINI MONITOR MODULE NZM -100 INTERFACE MODULE <br /> • Built -in type identification automatically identifies this de- • Supports compatible two -wire smoke detectors. <br /> vice as a ,monitor module to the FireWarden -100. • Supervises IDC wiring and connection of external power <br /> • Powered directly by two -wire SLC Loop. No additional source (resettable). <br /> power required. • High noise (EMF /RFI) immunity. <br /> • High noise (EMF /RFI) immunity. • SEMS screws with clamping plates for ease of wiring. <br /> • Tinned, stripped leads for ease of wiring. • Direct -dial entry of address (01 -99 for FireWarden -100). <br /> • Direct -dial entry of address (01 -99 for FireWarden -100). • LED flashes during normal operation. <br /> The NMM -100P Mini Monitor Module can be installed in a • LED latches steady to indicate alarm on command from <br /> single -gang junction directly behind the monitored unit. Its control panel. <br /> small size and light weight allow it to be installed without The NZM -100 Interface Module is intended for use in in- <br /> rigid mounting. The NMM -100P is intended for use in in- telligent, addressable systems, where the individual ad- <br /> telligent, two -wire systems where the individual address dress of each module is selected using built -in rotary <br /> of each module is selected using rotary switches. It pro- switches. This module allows intelligent panels to inter - <br /> vides a two -wire initiating device circuit for normally -open- face and monitor two -wire conventional smoke detectors. <br /> contact fire alarm and security devices. It transmits the status (normal, open, or alarm) of one full <br /> zone of conventional detectors back to the control panel. <br /> 1 0 1 ADDRESS 0 1 All two -wire detectors being monitored must be UL -com- <br /> 13 i, 2 2 patible with the module. <br /> 10 v 5 <br /> LOOP �� 4 NZM - 1 00 Applications — Use the NZM to moni <br /> tor a zone of two -wire smoke detectors. The monitored cir <br /> 9 8 7 s i g 8 6 3 cuit may be wired as an NFPA Style B (Class B) or Style D <br /> TENS ONES z, (Class A) Initiating Device Circuit. A 3.9 K ohm End -of -Line <br /> 1n 10 Resistor (provided) terminates the end of the Style B or D ig rl (class B or A) circuit (maximum IDC loop resistance is 25 <br /> o <br /> 1 ,_„ <br /> ohms). Install ELR across terminals 8 and 9 for Style D <br /> application. <br /> O J q v NZM - 100 Operation — Each NZM -100 uses one of <br /> p Q 99 (FireWarden -100) available module addresses on an EX 5 m <br /> panel SLC loop. and reports It its responds type to and regular the polls status from (open /norma control l/ <br /> short) of its Initiating Device Circuit (IDC). A flashing LED <br /> indicates that the module is in communication with the con- <br /> 1 1 I I trol panel. The LED latches steady on alarm (subject to <br /> current limitations on the loop). <br /> NMM - 100P Applications — Use to monitor a single NZM - 100 Specifications <br /> device or a zone of four -wire smoke detectors, manual fire Nominal operating voltage: 15 to 32 VDC. <br /> alarm pull stations, waterflow devices, or other normally - <br /> open dry- contact devices. May also be used to monitor nor- Maximum current draw: 5.1 mA (LED on). <br /> mally -open supervisory devices with special supervisory Average operating current: 270 pA (LED flashing). <br /> indication at the control panel. Monitored circuit/device is EOL resistance: 3.9K ohms. <br /> wired as an NFPA Style B (Class B) Initiating Device Cir- <br /> cuit. A 47K ohm End -of -Line Resistor (provided) terminates External supply voltage (between Terminals T3 and T4): <br /> the circuit. DC voltage: 18 to 28 volts power limited. Ripple voltage: <br /> NMM - 100P Operation — Each NMM -100P uses one 0.1 VRMS maximum. Current: 90 mA per module maximum. <br /> of 99 (FireWarden -100) available module addresses on <br /> Requires regulated, resettable 24 VDC power. <br /> an SLC loop. It responds to regular polls from the control Temperature range: 32 °F to 120 "F (0 °C to 49 °C). <br /> panel and reports its type and the status (open /normal/ Humidity range: 10% to 93% noncondensing. <br /> short) of its Initiating Device Circuit (IDC). Dimensions: 4.5" (11.43 cm) high x 4.0" (10.16 cm) wide x <br /> NMM - 100P Specifications 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square <br /> Nominal operating voltage: 15 to 32 VDC. x 2.125" (5.398 cm) deep box. <br /> Average operating current: 375 pA maximum. <br /> EOL resistance: 47K ohms. <br /> Temperature range: 32 °F to 120 °F (0 °C to 49 °C). <br /> Humidity range: 10% to 93% noncondensing. <br /> Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide <br /> x 0.5" (1.270 cm) deep. <br /> Wire length: 6.0" (15.24 cm) minimum. <br /> Page 2 of 3 — DN -6999 • 06/15/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.