My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9355
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:34:24 AM
Creation date
3/22/2011 8:30:24 AM
Metadata
Fields
Template:
Building Department
Company Name
NOM ZEPHYRHILLS LLC
Building Department - Doc Type
Permit
Permit #
09-9355
Building Department - Name
TIRE KINGDOM
Address
7540 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tqco /Fire & Building <br /> Products <br /> Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 <br /> Series TY -B — 5.6 K- factor <br /> Horizontal and Vertical Sidewall Sprinklers <br /> Standard Response, Standard Coverage <br /> General Corrosion resistant coatings, where <br /> applicable, are utilized to extend the <br /> life of copper alloy sprinklers beyond <br /> Description that which would otherwise be ob- , , <br /> The Series TY -B, 5.6 K- factor, Hori- tained when exposed to corrosive at- --- t j -- <br /> mospheres. Although corrosion resis- 0, 1 <br /> zontal and Vertical Sidewall Sprinklers tant coated sprinklers have passed the , , ,,, <br /> described in this data sheet are stand- standard corrosion tests of the appli- 'r <br /> and response - standard coverage, cable approval agencies, the testing is <br /> decorative 5 mm glass bulb type spray not representative of all possible cor- <br /> sprinklers designed for use in light and rosive atmospheres. Consequently, it ''� � ' <br /> W Y K . <br /> ordinary hazard, commercial occupan- is recommended that the end user be <br /> cies such as banks, hotels, shopping consulted with respect to the suitability <br /> malls, etc. They are designed for in- of these coatings for any given corro- <br /> stallation along a wall or the side of a sive environment. The effects of ambi- <br /> beam and just beneath a smooth ceil- ent temperature, concentration of <br /> ing. Sidewall sprinklers are commonly chemicals, and gas /chemical velocity, <br /> used instead of pendent or upright should be considered, as a minimum, <br /> sprinklers due to aesthetics or building along with the corrosive nature of the <br /> construction considerations, where chemical to which the sprinklers will be <br /> pble ing across the ceiling is not desir- exposed. <br /> The recessed version of the Series WARNINGS * E <br /> TY -B Horizontal Sidewall Sprinkler is The Series TY -8 Sprinklers described <br /> intended for use in areas with afin- herein must be installed and main- ., " <br /> ihed wall. It uses atwo -piece Style 10 tained in compliance with this docu- " <br /> Recessed Escutcheon. The Recessed ment, as well as with the applicable <br /> Escutcheon provides 1/2 inch (12,7 standards of the National Fire Protec- , <br /> mm) of recessed adjustment or up to tion Association, in addition to the <br /> 3/4 inch (19,1 mm) of total adjustment standards of any other authorities ha v- <br /> from the flush sidewall position. The ing jurisdiction. Failure to do so may <br /> adjustment provided by the Recessed impair the performance of these de- Technical <br /> Escutcheon reduces the accuracy to vices Data <br /> which the fixed pipe nipples to the The owner is responsible for maintain- <br /> sprinklers must be cut. ing their fire protection system and de- Approvals <br /> vices in proper operating condition. UL and C -UL Listed. <br /> The installing contractor or sprinkler FM, LPCB, and NYC Approved. <br /> manufacturer should be contacted (Refer to Table A for complete ap- <br /> with any questions. proval information including corrosion <br /> resistant status) <br /> IMPORTANT Maximum Working <br /> Always refer to Technical Data /�+ g Pressure <br /> Sheet TFP700 for the "INSTALLER Model /Sprinkler Refer to Table B. <br /> WARNING" that provides cautions Discharge Coefficient <br /> with respect to handling and instal- Identification K = 5.6 GPM / si <br /> lation of sprinkler systems and com- P ii2 (80,6 LPM /bar�� <br /> ponents. Improper handling and in- N umbers Temperature Ratings <br /> stallation can permanently damage Refer to Table A. <br /> a sprinkler system or its compo- TY3351 - Horizontal Finishes <br /> nents and cause the sprinkler to fail TY3451 - Vertical Sprinkler: Refer to Table A. <br /> to operate in a fire situation or cause Recessed Escutcheon: White Coated, <br /> it to operate prematurely. Chrome Plated, and Brass Plated. <br /> Page 1 of 6 APRIL, 2006 TFP161 <br />
The URL can be used to link to this page
Your browser does not support the video tag.