4" DIA. DBL. WALL <br />VENT THRU ROOF <br />DRAFT HOOD <br />SHUT OFF VALVE <br />COLD <br />TO GAS SUPPLY <br />MANUAL GAS <br />SHUT OFF <br />SEDIMENT TRAP/ <br />DRIP LEG <br />CAP <br />DRAIN VALVE <br />CATCH PAN DRAIN <br />TO MOP SINK <br />TRAFFIC TYPE <br />CAPPED CLEAN OUT <br />TYP. <br />SCH. 40 PVC <br />4" MIN. <br />OUTLET TO <br />SEWER LINE <br />MANHOLE COVERS <br />HEAVY DUTY CAST IRON FRAME AND COVER, <br />U.S. FOUNDRY NO, 225 -AS -ORS OR EQUAL. <br />"GREASE INTERCEPTOR" TO BE STAMPED <br />ON COVER. <br />THREADED PLUG <br />1 L. <br />L. <br />I_ L• J <br />GREASE TRAP SECTION N.T.S. <br />THE MINIMUM LIQUID CAPACITY IS TO BE 750 GAL. <br />(1 CU. FT. = 7.48 GAL. / 1 GAL. = 0.13 CU. FT.) <br />THE STRUCTURE CAN BE MADE OF PRECAST CONCRETE <br />WITH NO LESS THAN 4" WALLS IN NON- TRAFFIC AREA. <br />IN TRAFFIC AREAS WALLS ARE TO BE 6" TO 8" THICK. <br />2007 FLORIDA BUILDING CODE- PLUMBING <br />SECTIONS: 1003.5 AND 1003.5.1 <br />GREASE INTERCEPTOR CALCULATION: <br />(S) X (GS) X (HR /12) X (LF) X 0.75 = <br />8 X 10 X (10/12) X 1 X 0.75 = 50 GAL <br />MIN. 750 GAL. GREASE INTERCEPTOR PROVIDED <br />3/4" <br />3/4" <br />2 " <br />2 " <br />N <br />GAS METER <br />SHUT-OFF <br />MAXIMUM DEVELOPED LENGTH = 50 FT. <br />TOTAL BTU = 827,000 BTU <br />GAS WATER HEATER <br />THERMAL EXPANSION TANK <br />TEMPERATURE & PRESSURE <br />RELIEF VALVE <br />• SHUT OFF VALVE <br />OT <br />TO PUBLIC < <br />SANITARY <br />RELIEF VALVE DISCHARGE <br />LINE TO SUITABLE DRAIN <br />THERMOSTATIC <br />GAS VALVE <br />750 GAL. <br />GREASE TRAP <br />C <br />DRAIN TO MOP SINK <br />N.T.S. <br />THREADED PLUG <br />GAS STEAM TABLE <br />3/4 ", 20,000 BTU <br />SWEEP FLARES, TYP. <br />INLET FROM <br />FACILITY <br />2" MECH. <br />GAS VALVE pp`E' p O �1 <br />0�0 SUPPLY <br />o� <br />2 „ 1 1/4'' <br />GAS RISER DIAGRAM <br />N.T.S. <br />NOTE: 1. PROVIDE FLEXIBLE PIPE CONNECTION <br />TO ALL FRYERS AND RICE COOKER. <br />2. INTERCONNECT MECHANICAL GAS VALVE <br />WITH HOOD FIRE SUPPRESSION SYSTEM <br />BY FIRE SUPPRESSION CONTRACTOR. <br />3. DESIGNED NATURAL GAS PRESSURE TABLE 402.4(1) <br />0.5 PSI AND A PRESSURE DROP <br />0.3 INCH WATER COLUMN <br />4. GAS PIPING SHALL BE STEEL OR WROUGHT -IRON PIPE <br />FOR INTERIOR, GALVANIZED FOR EXTERIOR USE, AT <br />LEAST OF STANDARD WEIGHT (SCHEDULE 40) COMPLY <br />WITH ASME B36.10 OR ASTM A53. <br />PLUMBING 8 GAS PLAN SCALE : 1/411 - , -o <br />PLUMBING NOTES: <br />1. ALL HOT & COLD WATER LINE CONNECTION & PIPING SHALL BE ALL CPVC PER ASTM F 437, 438, 439 <br />HOT WATER LINE & DRAIN UNDER HANDICAP. LAVATORIES SHALL BE WRAPPED WITH INSULATION. <br />2. ALL UNDERGROUND & ABOVE GROUND SANITARY SOIL & \VENT TO BE SCH. 40 PVC PIPING <br />OR CAST IRON WHEN PENETRATE FIRE WALL. PROVIDE DRAINAGE SLOPE OF 1/4" PER FOOT. <br />3. INSTALL ESCUTCHEONS AT ALL EXPOSED WALL /CEILING PIPE PENETRATION. CAULK ALL GAPS <br />BETWEEN LAVATORY AND WALL AND UNDER COUNTERTOP SINK. <br />4. PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR /MATERIALS NECESSARY TO COMPLETE <br />THE ENTIRE SCOPE OF WORK AS OUTLINED ON THE DRAWINGS. THE CONSTRUCTION DOCUMENTS <br />ARE NOT INTENDED TO COVER ALL LABOR /MATERIALS NEEDED ITEM BY ITEM. <br />5. TEST : SANITARY & VENT PIPE TEST WITH MIN. 5' -0" HYDROSTATIC PRESSURE FOR 4 HOURS. <br />DOMASTIC WATER PIPE TEST WITH MIN. 150 PSI HYDROSTATIC PRESSURE FOR 2 HOURS. <br />6. ALL PLUMBING FIXTURES TO BE SELECTED /APPROVED BY OWNER. ALL TRIM TO BE CHROME FINISH. <br />7. IT IS THE RESPONSIBILITY OF PLUMBING CONTRACTOR TO VERIFY ALL EXISTING CONDITON SUCH <br />AS WATER /SEWER LINE SIZE AND LOCATION PRIOR TO SUBMIT PROPOSAL. <br />8. ALL WORKS SHALL COMPLY WITH STANDARD PLUMBING CODE AND LOCAL REQUIREMENTS. <br />HAND SINK <br />(3) COMP. SINK <br />I <br />c, I <br />TOILET RM <br />34 "C <br />v _ 1 H G --- .- .- .- .�- . -. -., <br />45 GAL. GAS <br />WATER HEATER <br />T_ <br />3�4 H - � - _/2 H <br />1/2" C \ STEAM TABLE <br />\ I <br />-MOP ,G ,/4 \\ <br />SINK �i \N <br />/ I / <br />�\ <br />1 2" SINK <br />C HAND L 1 / � H HAND <br />SINK <br />WATER RISER DIAGRAM N.T.S. <br />WATER a SEWER LINE CONNECTION CHART: <br />ITEM OF CONNECTION <br />COLD <br />HOT <br />DRAIN <br />REMARK <br />ELECT. WATER HEATER <br />/ r <br />3/4" <br />"- <br />3 COMP. SINK <br />1/2" <br />1/2" <br />2" <br />. <br />F- CONCRETE <br />1/2" <br />1 1/2" <br />W/ STUDOR VENT <br />FLOOR MOP SINK <br />1/2" <br />1/2 ", <br />3 <br />BAFFLE <br />1/2" <br />N/A <br />3" <br />3 WATER CONNECT. W/ BALL VALVE (COUNSULT W/ OWNER) <br />STEAM TABLE <br />N/A <br />1/2" <br />1 <br />1" COPPER DRAIN W/ BALL VALVE <br />WATER CLOSET <br />1/2" <br />N/A <br />4" <br />CD <br />LAVATORY <br />1/2" <br />1/2" <br />1 1/2" <br />1 INSULATE ALL EXPOSED DRAIN AND WATER LINE <br />LIQUID LEVEL <br />Q <br />N <br />J <br />w <br />W <br />rn <br />°° <br />c0 <br />0 <br />O <br />J <br />U <br />Li <br />N <br />w <br />N <br />z <br />�.- <br />V) <br />1/3 <br />DESIGN ::; <br />z <br />° <br />a.. <br />2/3 DESIGN <br />VOLUME ;' <br />Q <br />VOLUME <br />C) <br />C) <br />Z <br />00 <br />0 <br />00 <br />w ul <br />U <br />♦� <br />V <br />U <br />\— <br />1 L. <br />L. <br />I_ L• J <br />GREASE TRAP SECTION N.T.S. <br />THE MINIMUM LIQUID CAPACITY IS TO BE 750 GAL. <br />(1 CU. FT. = 7.48 GAL. / 1 GAL. = 0.13 CU. FT.) <br />THE STRUCTURE CAN BE MADE OF PRECAST CONCRETE <br />WITH NO LESS THAN 4" WALLS IN NON- TRAFFIC AREA. <br />IN TRAFFIC AREAS WALLS ARE TO BE 6" TO 8" THICK. <br />2007 FLORIDA BUILDING CODE- PLUMBING <br />SECTIONS: 1003.5 AND 1003.5.1 <br />GREASE INTERCEPTOR CALCULATION: <br />(S) X (GS) X (HR /12) X (LF) X 0.75 = <br />8 X 10 X (10/12) X 1 X 0.75 = 50 GAL <br />MIN. 750 GAL. GREASE INTERCEPTOR PROVIDED <br />3/4" <br />3/4" <br />2 " <br />2 " <br />N <br />GAS METER <br />SHUT-OFF <br />MAXIMUM DEVELOPED LENGTH = 50 FT. <br />TOTAL BTU = 827,000 BTU <br />GAS WATER HEATER <br />THERMAL EXPANSION TANK <br />TEMPERATURE & PRESSURE <br />RELIEF VALVE <br />• SHUT OFF VALVE <br />OT <br />TO PUBLIC < <br />SANITARY <br />RELIEF VALVE DISCHARGE <br />LINE TO SUITABLE DRAIN <br />THERMOSTATIC <br />GAS VALVE <br />750 GAL. <br />GREASE TRAP <br />C <br />DRAIN TO MOP SINK <br />N.T.S. <br />THREADED PLUG <br />GAS STEAM TABLE <br />3/4 ", 20,000 BTU <br />SWEEP FLARES, TYP. <br />INLET FROM <br />FACILITY <br />2" MECH. <br />GAS VALVE pp`E' p O �1 <br />0�0 SUPPLY <br />o� <br />2 „ 1 1/4'' <br />GAS RISER DIAGRAM <br />N.T.S. <br />NOTE: 1. PROVIDE FLEXIBLE PIPE CONNECTION <br />TO ALL FRYERS AND RICE COOKER. <br />2. INTERCONNECT MECHANICAL GAS VALVE <br />WITH HOOD FIRE SUPPRESSION SYSTEM <br />BY FIRE SUPPRESSION CONTRACTOR. <br />3. DESIGNED NATURAL GAS PRESSURE TABLE 402.4(1) <br />0.5 PSI AND A PRESSURE DROP <br />0.3 INCH WATER COLUMN <br />4. GAS PIPING SHALL BE STEEL OR WROUGHT -IRON PIPE <br />FOR INTERIOR, GALVANIZED FOR EXTERIOR USE, AT <br />LEAST OF STANDARD WEIGHT (SCHEDULE 40) COMPLY <br />WITH ASME B36.10 OR ASTM A53. <br />PLUMBING 8 GAS PLAN SCALE : 1/411 - , -o <br />PLUMBING NOTES: <br />1. ALL HOT & COLD WATER LINE CONNECTION & PIPING SHALL BE ALL CPVC PER ASTM F 437, 438, 439 <br />HOT WATER LINE & DRAIN UNDER HANDICAP. LAVATORIES SHALL BE WRAPPED WITH INSULATION. <br />2. ALL UNDERGROUND & ABOVE GROUND SANITARY SOIL & \VENT TO BE SCH. 40 PVC PIPING <br />OR CAST IRON WHEN PENETRATE FIRE WALL. PROVIDE DRAINAGE SLOPE OF 1/4" PER FOOT. <br />3. INSTALL ESCUTCHEONS AT ALL EXPOSED WALL /CEILING PIPE PENETRATION. CAULK ALL GAPS <br />BETWEEN LAVATORY AND WALL AND UNDER COUNTERTOP SINK. <br />4. PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR /MATERIALS NECESSARY TO COMPLETE <br />THE ENTIRE SCOPE OF WORK AS OUTLINED ON THE DRAWINGS. THE CONSTRUCTION DOCUMENTS <br />ARE NOT INTENDED TO COVER ALL LABOR /MATERIALS NEEDED ITEM BY ITEM. <br />5. TEST : SANITARY & VENT PIPE TEST WITH MIN. 5' -0" HYDROSTATIC PRESSURE FOR 4 HOURS. <br />DOMASTIC WATER PIPE TEST WITH MIN. 150 PSI HYDROSTATIC PRESSURE FOR 2 HOURS. <br />6. ALL PLUMBING FIXTURES TO BE SELECTED /APPROVED BY OWNER. ALL TRIM TO BE CHROME FINISH. <br />7. IT IS THE RESPONSIBILITY OF PLUMBING CONTRACTOR TO VERIFY ALL EXISTING CONDITON SUCH <br />AS WATER /SEWER LINE SIZE AND LOCATION PRIOR TO SUBMIT PROPOSAL. <br />8. ALL WORKS SHALL COMPLY WITH STANDARD PLUMBING CODE AND LOCAL REQUIREMENTS. <br />HAND SINK <br />(3) COMP. SINK <br />I <br />c, I <br />TOILET RM <br />34 "C <br />v _ 1 H G --- .- .- .- .�- . -. -., <br />45 GAL. GAS <br />WATER HEATER <br />T_ <br />3�4 H - � - _/2 H <br />1/2" C \ STEAM TABLE <br />\ I <br />-MOP ,G ,/4 \\ <br />SINK �i \N <br />/ I / <br />�\ <br />1 2" SINK <br />C HAND L 1 / � H HAND <br />SINK <br />WATER RISER DIAGRAM N.T.S. <br />WATER a SEWER LINE CONNECTION CHART: <br />ITEM OF CONNECTION <br />COLD <br />HOT <br />DRAIN <br />REMARK <br />ELECT. WATER HEATER <br />3/4" <br />3/4" <br />1 <br />3 COMP. SINK <br />1/2" <br />1/2" <br />2" <br />HAND SINK <br />1/2" <br />1/2" <br />1 1/2" <br />W/ STUDOR VENT <br />FLOOR MOP SINK <br />1/2" <br />1/2 ", <br />3 <br />GAS COOK WOK <br />1/2" <br />N/A <br />3" <br />3 WATER CONNECT. W/ BALL VALVE (COUNSULT W/ OWNER) <br />STEAM TABLE <br />N/A <br />1/2" <br />1 <br />1" COPPER DRAIN W/ BALL VALVE <br />WATER CLOSET <br />1/2" <br />N/A <br />4" <br />CD <br />LAVATORY <br />1/2" <br />1/2" <br />1 1/2" <br />1 INSULATE ALL EXPOSED DRAIN AND WATER LINE <br />V <br />Q <br />0 <br />a <br />TO PUBLIC <. - <br />SANITARY 4 <br />750 GAL. GREASE TRAP <br />BURIED IN GROUND <br />EXIST. V.T.R. W/ STUDOR VENT <br />J� 12 "X12" FLR SINK 0 <br />EXIST. 4" SANITARY 311 F. D. 2" VENT uj <br />- <br />4 11 <br />c. o. � <br />TIE TO EXIST. 4" LAV. <br />TOILET DRAIN 411 4" SANITARY od <br />C.O. 4 " z <br />W.C. Q <br />C.O. <br />4 4" GREASE <br />4 11 4 11 <br />3 3 <br />4 " <br />2007 FLORIDA BUILDING CODE- PLUMBING 2" VENT <br />SECTIONS: 1003.5 AND 1003.5.1 '' <br />GREASE INTERCEPTOR CALCULATION: ^ I LAV. F.D. 3 <br />(S) X (GS) X (HR /12) X (LF) X 0.75 = v <br />8 X 10 X (10/12) X 1 X 0.75 = 50 GAL 3 <br />MIN. 750 GAL. GREASE INTERCEPTOR PROVIDED 411 <br />MOP SINK <br />3 " <br />4" HUB DRAIN <br />W/ STUDOR VENT <br />PLUMBING RISER DIAGRAM N.T.S. <br />1) PROVIDE 1/2" C.W. PRIMER FOR ALL FLOOR DRAINS PER CODE. <br />2) TIE ALL VENTS TO EXISTING VENT THROUGH ROOF. <br />.j <br />0. <br />1 3" HUB <br />4" <br />z <br />4" HUB DRAIN <br />W/ STUDOR VENT <br />.12 <br />Q <br />z <br />w <br />.12 <br />0 <br />C) <br />0 <br />CD <br />\ w <br />d <br />w <br />Q <br />N <br />J <br />w <br />W <br />rn <br />°° <br />c0 <br />0 <br />O <br />J <br />U <br />Li <br />N <br />w <br />z <br />�.- <br />V) <br />— <br />_ <br />z <br />° <br />a.. <br />U <br />w <br />Q <br />C) <br />C) <br />Z <br />w <br />z <br />0 <br />w ul <br />U <br />♦� <br />V <br />U <br />\— <br />o <br />z <br />o_ <br />U) <br />w <br />cif <br />rn <br />o <br />� <br />Q) <br />o <br />CN <br />z <br />vi <br />vi Q <br />o <br />z <br />� <br />m <br />w <br />m <br />z <br />W <br />LLJ <br />U J <br />C) <br />orf <br />a <br />Q 0:f <br />w <br />m U <br />U Cn <br />I._. <br />z <br />Ln <br />m <br />r- <br />Ln <br />�--- <br />w <br />W <br />= <br />I- <br />Z <br />z <br />a <br />LL <br />> <br />O <br />c <br />O <br />m <br />� <br />Z <br />w <br />z <br />w CF) <br />Lij <br />U <br />N I�- <br />N <br />r <br />� 21�pGfi <br />SHENG <br />MING WANG <br />AR 14222 <br />