Laserfiche WebLink
• <br /> July 14, 2004 DF -52121 • E -325 <br /> 6 FI re•LITe� ALarmS MMF- 300(A) Series /MDF -300 <br /> Addressable Monitor Modules <br /> www.firelite.com Section Addressable Devices <br /> GENERAL <br /> California <br /> Four different monitor modules are available for Fire•Lite E State Fire <br /> Alarm's MS -9200. MS- 92000D and MS -9600 intelligent fire 11; Marshal <br /> alarm control panels to suit a variety of applications. Moni- �7300- 0075:185 <br /> tor modules are used to supervise a circuit of dry- contact -- <br /> input devices, such as conventional heat detectors and pull Ul It> <br /> stations, or monitor and power a circuit of two -wire smoke <br /> detectors (MMF -302). APPROVED <br /> MMF - 300 (Replaces M300) — The MMF -300 Moni- LISTED 4111) <br /> tor Module is a standard -sized module (typically mounts to a CSXXXX <br /> 4" [101.6 mm] square box) that supervises either a Class A <br /> (Style D) or Class B (Style B) circuit of dry- contact input de- <br /> vices. DUAL -MciN <br /> MMF -301 (Replaces M301) — The MMF - 301 is a Min- <br /> iature Monitor Module (a mere 1.3" (33.02 mm) H x 2.75" <br /> (69.85 mm) W x 0.5" (12.70 mm) D) used to supervise a <br /> Class B (Style B) circuit. Its compact design allows the <br /> MMF -301 to be mounted in a single -gang box behind the <br /> device it is monitoring. <br /> MMF - 302 (Replaces M302) <br /> ( p ) —The M - 3 02 Inter- ,' <br /> face Module is a standard -sized module used to monitor and <br /> supervise compatible two -wire, 24 volt, smoke detectors on )° <br /> li <br /> a Class A (Style D) or Class B (Style B) circuit. { <br /> MDF - 300 (New) — The MDF -300 Dual Monitor Module <br /> is a standard -sized module (typically mounts to a 4" [101.6 <br /> mm] square box) that supervises two Class B (Style B) cir <br /> cuits of dry- contact input devices. _ <br /> s <br /> MMF -300 MONITOR MODULE <br /> • Built -in type identification automatically identifies this de- MDF -300 <br /> vice as a monitor module to the control panel <br /> • Powered directly by two -wire SLC loop. No additional Device Circuit. A 47K ohm End -of -Line Resistor (provided) <br /> terminates the Style 8 circuit. No resistor is required for <br /> power required. supervision of the Style D circuit. Maximum IDC resistance <br /> • High noise (EMF /RFI) immunity. is 1,500 ohms. <br /> • SEMS screws with clamping plates for ease of wiring. MMF - 300 Operation — Each MMF -300 uses one of <br /> • Direct Decade 01 – 99 (MS -9200 and MS- 92000D) and 99 (MS -9200 and MS- 92000D) or 159 (MS -9600) avail - <br /> 01 -159 (MS -9600) entry of address. able module addresses on an SLC loop. It responds to <br /> • LED flashes red during normal operation and latches regular polls from the control panel and reports its type <br /> on steady to indicate alarm. and the status (open /normal /short) of its Initiating Device <br /> The MMF - 300 Monitor Module is intended for use in intel- Circuit (IDC). A flashing LED indicates that the module is <br /> ligent, two -wire systems, where the individual address of in communication with the control panel. The LED latches <br /> each module is selected using the built -in rotary switches, steady on alarm (subject to current limitations on the loop). <br /> It provides either a two -wire or four -wire Class A or Class MMF - 300 Specifications <br /> B fault - tolerant Initiating Device Circuit (IDC) for normally - <br /> open- contact fire alarm and supervisory devices. The MMF- Nominal operating voltage: 15 to 32 VDC. <br /> 300 can be used to replace M300 modules in existing sys- Maximum current draw: 5.1 mA (LED on). <br /> tems. Average operating current: 400 iA (LED flashing). <br /> MMF -300 Applications — Use to monitor a zone of EOL resistance: 47K ohms. <br /> four -wire smoke detectors, manual fire alarm pull stations, <br /> waterflow devices, or other normally -open dry- contact alarm Temperature range: 32 °F to 120 °F (0 °C to 49°C) <br /> activation devices. May also be used to monitor normally- Humidity range: 10% to 93% noncondensing. <br /> open supervisory devices with special supervisory indica- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x <br /> tion at the control panel. Monitored circuit may be wired as 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square <br /> an NFPA Style B (Class B) or Style D (Class D) Initiating x 2.125" (53.975 mm) deep box. <br /> h ocu m W <br /> Alarms is a Honeywell company. <br /> This ISO 9001 <br /> This docuent is not intended to be used for installation purposes. e try to keep our product <br /> information up -to -date and accurate. We cannot cover all specific applications or anticipate all <br /> requirements. All specifications are subject to change without notice. C E RT 1 F 1 E <br /> For more information, contact Fire -Lite Alarms. One Fire -Lite Place, Northford, Connecticut 06472. EN61ME11NC &MANBFACIBBIN6 <br /> Phone: (800) 627 -3473, Toll -Free FAX. (877) 699 -4105. QUALITY SYSTEM S <br /> DF -52121 • 07/14/04 — Page 1 of 3 <br />