My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9662
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9662
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 10:05:10 AM
Creation date
3/22/2011 10:03:00 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS LLC
Building Department - Doc Type
Permit
Permit #
09-9662
Building Department - Name
ZEPHYR COMMONS LLC
Address
7940 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MMF -301 MINI MONITOR MODULE MMF -302 INTERFACE MODULE <br /> • Built -in type identification automatically identifies this • Supports compatible two -wire smoke detectors. <br /> . device as a monitor module to the MS -9200, MS- • Supervises IDC wiring and connection of external power <br /> 92000D or MS -9600. source (resettable). <br /> • Powered directly by two -wire SLC Loop. No additional • High noise (EMF /RF!) immunity. <br /> power required. • SEMS screws with clamping plates for ease of wiring. <br /> • High noise (EMF /RFI) immunity. • Direct -dial entry of address (01 -99 for MS- 9200 /MS- <br /> • Tinned, stripped leads for ease of wiring. 92000D, 01 -159 for MS- 9600). <br /> • Direct -dial entry of address (01 -99 for MS- 9200 /MS- • LED flashes during normal operation. <br /> 92000D, 01 -159 for MS- 9600). • LED latches steady to indicate alarm on command from <br /> The MMF -301 Mini Monitor Module can be installed in a control panel. <br /> single -gang junction directly behind the monitored unit. Its The MMF -302 Interface Module is intended for use in intel- <br /> small size and light weight allow it to be installed without ligent, addressable systems, where the individual address <br /> rigid mounting. The MMF -301 is intended for use in intelli- of each module is selected using built -in rotary switches. <br /> gent, two -wire systems where the individual address of This module allows intelligent panels to interface and moni- <br /> each module is selected using rotary switches. It provides tor two -wire conventional smoke detectors. It transmits the <br /> a two -wire initiating device circuit for normally- open -con- status (normal, open, or alarm) of one full zone of conven- <br /> tact fire alarm and security devices. The MMF -301 can be tional detectors back to the control panel. All two -wire de- <br /> used to replace M301 module in existing systems. tectors being monitored must be UL compatible with the <br /> module. <br /> 15 0 ADDRESS 0 I <br /> 1 13 14 1 2 i MMF -302 Applications — Use the MMF -302 to moni- <br /> 12 � _2 - 3 �1 ( t. tor a zone of two -wire smoke detectors. The monitored cir- <br /> )) LOOP ( �i/ )) j4 may Style (Class B) Style 13' c uit ma be wired as an NFPA S le B Class B or S le D <br /> 11 y�'„ 14� <br /> S r <br /> 10 \.,: %5' (Class A) Initiating Device Circuit. A 3.9 K ohm End -of -Line <br /> 9 8 7 6 l 9'S �' Resistor (provided) terminates the end of the Style B or D <br /> TENS ONES (class B or A) circuit (maximum IDC loop resistance is 25 <br /> ,i4 ���I 11 <br /> I ! ohms). Install ELR across terminals 8 and 9 for Style D <br /> - application. <br /> MMF -302 Operation — Each MMF -302 uses one of <br /> E 159 available module addresses on a MS -9600 SLC loop. <br /> It uses one of 99 on a MS -9200 or MS- 92000D. It responds <br /> to regular polls from the control panel and reports its type <br /> ° <br /> zi_ and the status (open /normal /short) of its Initiating Device <br /> 2 Circuit (IDC). A flashing LED indicates that the module is <br /> in communication with the control panel. The LED latches <br /> r steady on alarm (subject to current limitations on the loop). <br /> I J u <br /> MMF -302 Specifications <br /> Nominal operating voltage: 15 to 32 VDC. <br /> MMF -301 Applications — Use to monitor a single Maximum current draw: 5.1 mA (LED on). <br /> device or a zone of four -wire smoke detectors, manual fire Average operating current: 270 pA (LED flashing). <br /> alarm pull stations, waterflow devices, or other normally -open <br /> dry- contact devices. May also be used to monitor normally- EOL resistance: 3.9K ohms. <br /> open supervisory devices with special supervisory indica- External supply voltage (between Terminals T3 and T4): <br /> Lion at the control panel. Monitored circuit /device is wired DC voltage: 18 to 28 volts power limited. Ripple voltage: <br /> as an NFPA Style B (Class B) Initiating Device Circuit. A 47K 0.1 VRMS maximum. Current: 90 mA per module maximum. <br /> ohm End -of -Line Resistor (provided) terminates the circuit. Requires regulated, resettable 24 VDC power. <br /> MMF -301 Operation — Each MMF -301 uses one of Temperature range: 32 °F to 120 °F (0 °C to 49 °C). <br /> 159 available module addresses on an SLC loop MS- Humidity range: 10% to 93% noncondensing. <br /> 9600. It uses one of 99 on a MS -9200 or MS- 92000D. It <br /> responds to regular polls from the control panel and re- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x <br /> ports its type and the status (open /normal /short) of its Ini 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square <br /> tiating Device Circuit (IDC). x 2.125" (53.975 mm) deep box. <br /> MMF -301 Specifications MDF -300 DUAL MONITOR MODULE <br /> Nominal operating voltage: 15 to 32 VDC. • Built -in type identification automatically identifies this de- <br /> Average operating current: 375 pA maximum. vice as two monitor modules to the control panel <br /> EOL resistance: 47K ohms. • Powered directly by the two -wire SLC loop. No addi- <br /> Temperature range: 32 °F to 120 °F (0 °C to 49 °C). tional power required. <br /> 0 0 • High noise (EMF /RFI) immunity. <br /> Humidity range: 10% to 93% noncondensing. • SEMS screws with clamping plates for ease of wiring. <br /> Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide • Direct -dial entry of address (01 — 159 on the MS -9600, <br /> x 0.5" (12.70 mm) deep. 01 -99 for MS- 92001MS- 92000D). <br /> Wire length: 6" (152.4 mm) minimum. • LED flashes red during normal operation and latches <br /> on steady red to indicate alarm. <br /> Page 2 of 3 — DF -52121 • 07/14/04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.