My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10030
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10030
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:00:57 AM
Creation date
3/22/2011 10:56:53 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYRHILLS FIRE DEPARTMENT
Building Department - Doc Type
Permit
Permit #
10-10030
Building Department - Name
ZEPHYRHILLS FIRE DEPARTMENT
Address
38410 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br /> System Capacity 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring <br /> (TR- CE -B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. <br /> • Intelligent Signalling Line Circuits 1 <br /> • Addressable device capacity 198 Shipping Specifications <br /> • Programmable software zones 99 <br /> • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) <br /> high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. <br /> • ANN -bus devices 8 <br /> Electrical Specifications <br /> Temperature and Humidity Ranges <br /> This system meets NFPA requirements for operation at 0 - <br /> AC Power: FireWarden -100 -2 Rev 2: 120 VAC, 60 Hz, 3.0 49 °C/32 -120 °F and at a relative humidity 93% ± 2% RH <br /> amps. FireWarden -100 -2 Rev 2(E): 240 VAC, 50 Hz, 1.5 amps. (noncondensing) at 32 °C ± 2 °C (90 °F ± 3 °F). However, the <br /> Wire size: minimum 14 AWG (2.00 mm with 600 V insulation. useful life of the system's standby batteries and the electronic <br /> Battery: Two 12 V 18AH lead -acid batteries. components may be adversely affected by extreme tempera - <br /> Battery charger capacity: 7 -18 AH. FireWarden -100 -2 Rev ture ranges and humidity. Therefore, it is recommended that <br /> 2 cabinet holds maximum of two 18 AH batteries. this system and its peripherals be installed in an environment <br /> with a normal room temperature of 15 - 27 °C /60 - 80 °F. <br /> Communication Loop: Supervised and power - limited. <br /> Notification Appliance Circuits: Each terminal block pro- NFPA Standards <br /> vides connections for two Style Y (Class B) or one Style Z <br /> (Class A) for a total of four Style Y (Class B) or two Style Z The FireWarden 100 2 Rev 2 complies with the following <br /> (Class A) NACs. Maximum signaling current per circuit: 2.5 NFPA 72 Fire Alarm Systems requirements: <br /> amps. End -of -Line Resistor: 4.7K ohm, 1/2 watt (P /N 71252 - LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> UL listed) for Style Y (Class B) NAC. Refer to panel documen- Supervisory). <br /> tation and Notifier Device Compatibility Document for listed - AUXILIARY (Automatic, Manual and Waterflow) (requires <br /> compatible devices. 4XTM). <br /> Two Programmable Relays and One Fixed Trouble Relay: - REMOTE STATION (Automatic, Manual, Waterflow and <br /> Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 Sprinkler Supervisory) (Where a DACT is not accepted, <br /> VAC (resistive). Form -C relays. the alarm, trouble and supervisory relays may be con - <br /> Special Application Power (24 VDC Nominal): Jumper nected to UL 864 listed transmitters. For reverse polarity <br /> selectable (JP4) for conversion to resettable power output. Up signaling of alarm and trouble, 4XTM is required.) <br /> to 0.3 amps total DC current available from each output. - PROPRIETARY (Automatic, Manual, Waterflow and <br /> Power - limited. Sprinkler Supervisory). <br /> Four -Wire Resettable Special Application Smoke Detector - CENTRAL STATION (Automatic, Manual, Waterflow and <br /> Power (24 VDC nominal): Up to 0.3 amps for powering four- Sprinkler Supervisory). <br /> wire smoke detectors. Power - limited. Refer to the Notifier - OT, PSDN (Other Technologies, Packet - switched Data <br /> Device Compatibility Document for listed compatible devices. Network) <br /> Remote Sync Output: Remote power supply synchronization <br /> output. Nominal special application power: 24 VDC. Maximum Agency Listings and Approvals <br /> current: 40 mA. End -of -Line Resistor: 4.7K ohm. Output linked <br /> to NAC 1 control. Supervised and power - limited. The listings and approvals below apply to the basic FireWar- <br /> den -100 -2 Rev 2 control panel. In some cases, certain mod - <br /> Telephone Interface: Unless used with Teldat VISORALARM, ules may not be listed by certain approval agencies, or listing <br /> requires dedicated business telephone number with a mini- may be in process. Consult factory for latest listing status. <br /> mum of 5 volts DC (off -hook voltage). Obtain dedicated phone • UL: S635 <br /> line directly from your local phone company. Do not use shared <br /> phone lines or PBX (digital) type phone line extensions. • FM approved <br /> • CSFM: 7165- 0028:235 <br /> Cabinet Specifications • MEA: 120 -06 -E, Volume 2 <br /> Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x <br /> 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x <br /> FireWarden® and Notifier® are registered trademarks of Honeywell <br /> International Inc. Microsoft® and Windows® are registered trademarks of the <br /> Microsoft Corporation. <br /> ®2009 by Honeywell International Inc. All rights reserved. Unauthorized use <br /> of this document is strictly prohibited. <br /> 1S0 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up -to -date and accurate. <br /> C E R T 1 F 1 E We cannot cover all specific applications or anticipate all requirements. <br /> B EREMIIR ` AWARMIIIM6 All specifications are subject to change without notice. <br /> QUALITY SYSTEMS Made in the U.S. A. <br /> For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. <br /> www.notifier.com <br /> Page 6 of 6 — DN- 60417:C • 12/17/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.