DN- 7001:C • A1-380 <br /> NOT -BGI 2LX(A) N OTI F 1 E R <br /> Addressable Manual Pull Station <br /> For FireWarden Series Panels by Honeywell <br /> Intelligent/Addressable Devices <br /> General <br /> • B •' a+X.rr..anxh.:i2.tiv .+„... ,....;,;. <br /> The Notifier NOT- BG12LX is a state -of- the -art, dual- action , ,� <br /> (i.e., requires two motions to activate the station) pull station <br /> that includes an addressable interface for FireWarden series" <br /> intelligent control panels. Because the NOT-BG12LX is `a <br /> addressable, the control panel can display the exact location of <br /> activated manual station. This leads fire personnel quickly <br /> to the location of the alarm. <br /> nor � t '� gg <br /> Features PULL <br /> • Maintenance personnel can open station for inspection and <br /> address setting without causing an alarm condition. <br /> • Built -in bicolor LED, which is visible through the handle of 1, <br /> the station, flashes in normal operation and latches steady <br /> red when in alarm. <br /> • Handle latches in down position and the word "ACTIVATED" <br /> appears to clearly indicate the station has been operated. 'g <br /> • Captive screw terminals wire -ready for easy connection to loop (accepts up to 12 AWG /3.25 mm wire). *. <br /> • Can be surface mounted (with SB -10 or SB -I /O) or semi- <br /> flush mounted. Semi -flush mount to a standard single - <br /> gang, double -gang, or 4' (10.16 cm) square electrical box. <br /> • Smooth dual- action design. The NOT BG12LX <br /> • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station <br /> lines (Section 4.1.3[13]); meets ADA requirement for 5 Ib. <br /> maximum activation force. <br /> • Highly visible. The BG12TR is usually needed for semi -flush mounting with 4' <br /> • Attractive shape and textured finish. (10.16 cm) or double -gang boxes (not with single -gang boxes). <br /> • Key reset. <br /> • Includes Braille text on station handle. Operation <br /> • Optional trim ring (BG12TR). Pushing in, then pulling down on the handle causes it to latch <br /> Meets UL 38, Standard for Si in the down /activated position. Once latched, the word "ACTT- <br /> • Manually Actuated Signaling 9 VATED" (in bright yellow) appears at the top of the handle, <br /> Boxes. while a portion of the handle protrudes from the bottom of the <br /> station. To reset the station, simply unlock the station with the <br /> Construction key and pull the door open. This action resets the handle; dos - <br /> Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. <br /> material with a textured finish. Each manual station, on command from the control panel, <br /> sends data to the panel representing the state of the manual <br /> Specifications switch. Two rotary decimal switches allow address settings <br /> (1 — 99 on NFW2- 100 /NFW2 -100C, 1 — 50 for NFW- 50 /NFW- <br /> • Shipping Weight: 9.6 oz. (272.15 g) 50C). <br /> • Normal operating voltage: 24 VDC. <br /> • Maximum SLC loop voltage: 28.0 VDC. Architectural/Engineering <br /> • Maximum SLC loop current: NA. Specifications <br /> • Temperature Range: 32 °F to 120 °F (0 °C to 49 °C) Manual Fire Alarm Stations shall be non - coded, with a key- <br /> • Relative Humidity: 10% to 93% (noncondensing) operated reset lock in order that they may be tested, and so <br /> • For use indoors in a dry location designed that after actual Emergency Operation, they cannot <br /> be restored to normal except by use of a key. An operated sta- <br /> Installation tion shall automatically condition itself so as to be visually <br /> detected as activated. Manual stations shall be constructed of <br /> The NOT-BG12LX will mount semi -flush into a single -gang, red - colored polycarbonate material with clearly visible operat- <br /> double -gang, or standard 4' (10.16 cm) square electrical outlet ing instructions provided on the cover. The word FIRE shall <br /> box, or will surface mount to the model SB -10 or SB -I /O sur- appear on the front of the stations in white letters, 1.00 inches <br /> face backbox. If the NOT-BG12LX is being semi -flush (2.54 cm) or larger. Stations shall be suitable for surface <br /> mounted, then the optional trim ring (BG12TR) may be used. mounting on matching backbox SB -10 or SB -I /O; or semi -flush <br /> mounting on a standard single -gang, double -gang, or 4' <br /> (10.16 cm) square electrical box, and shall be installed within <br /> DN- 7001:C • 09/18/2009 — Page 1 of 2 <br />