do 6999:b1 <br /> Monitor Modules <br /> NMM- 100(A), NMM- 100P(A), NZM- N OT I F 1 E R <br /> 100(A ), and NDM-100(A) <br /> for FireWarden Series Panels by Honeywell <br /> Intelligent Addressable Devices <br /> General <br /> Four different monitor modules are available for Notifier's Fire- <br /> Warden Series intelligent control panels for a variety of appli- <br /> cations. Monitor modules supervise a circuit of dry- contact r t <br /> input devices, such as conventional heat detectors and pull, <br /> stations, or monitor and power a circuit of two -wire smoke's t <br /> i <br /> detectors (NZM- 100(A)). ,a .., t x <br /> NMM- 100(A) is a standard -sized module (typically mounts to a <br /> 4" [10.16 cm] square box) that supervises either a Style D <br /> (Class A) or Style B (Class B) circuit of dry- contact input <br /> devices. gra <br /> NMM- 100P(A) is a miniature monitor module a mere 1.3" 71.k., ,wt'ra <br /> (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that of <br /> supervises a Style B (Class B) circuit of dry- contact input <br /> devices. Its compact design allows the NMM- 100P(A) to often <br /> be mounted in a single -gang box behind the device it monitors. <br /> NZM- 100(A) is a standard -sized module that monitors and <br /> supervises compatible two -wire, 24 volt, smoke detectors on a <br /> Style D (Class A) or Style B (Class B) circuit. <br /> NDM- 100(A) is a standard -sized dual monitor module that NMM- 100(A) (Type H) <br /> monitors and supervises two independent two -wire Style B <br /> (Class B) dry - contact initiating device circuits (IDCs) at two <br /> separate, consecutive addresses in intelligent, two -wire systems. NMM- 100(A) OPERATION <br /> Each NMM- 100(A) uses one of the available module <br /> NMM- 100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from <br /> • Built -in type identification automatically identifies this device the control panel and reports its type and the status (open/nor- <br /> as a monitor module to the control panel. mal /short) of its Initiating Device Circuit (IDC). A flashing LED <br /> indicates that the module is in communication with the control <br /> • Powered directly by two -wire SLC loop. No additional power panel. The LED latches steady on alarm (subject to current <br /> required. limitations on the loop). <br /> • High noise (EMF /RFI) immunity. <br /> • SEMS screws with clamping plates for ease of wiring. NMM- 100(A) SPECIFICATIONS <br /> • Direct Decade entry of address: 01 — 99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. <br /> 100 -2, 01 — 50 on FireWarden -50. Maximum current draw: 5.0 mA (LED on). <br /> • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 com- <br /> to indicate alarm. munication every 5 seconds, 47k EOL. <br /> The NMM- 100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance: 40 ohms. <br /> gent, two -wire systems, where the individual address of each <br /> module is selected using the built -in rotary switches. It pro EOL resistance: 47K ohms. <br /> vides either a two -wire or four -wire fault - tolerant Initiating Temperature range: 32 °F to 120 °F (0 °C to 49 °C). <br /> Device Circuit (IDC) for normally- open- contact fire alarm and <br /> supervisory devices. The module has a panel - controlled LED Humidity range: 10% to 93% noncondensing. <br /> indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> NMM- 100(A) APPLICATIONS 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> 2.125" (5.398 cm) deep box. <br /> Use to monitor a zone of four -wire smoke detectors, manual <br /> fire alarm pull stations, waterflow devices, or other normally- NMM- 100P(A) Mini Monitor Module <br /> open dry- contact alarm activation devices. May also be used <br /> • Built -in type identification automatically identifies this device <br /> to monitor normally -open supervisory devices with special <br /> supervisory indication at the control panel. Monitored circuit as a monitor module to the panel. <br /> may be wired as an NFPA Style B (Class B) or Style D (Class • Powered directly by two -wire SLC loop. No additional power <br /> A) Initiating Device Circuit. A 47K ohm End -of -Line Resistor required. <br /> (provided) terminates the Style B circuit. No resistor is • High noise (EMF /RFI) immunity. <br /> required for supervision of the Style D circuit. <br /> • Tinned, stripped leads for ease of wiring. <br /> • Direct Decade entry of address: 01 — 99 on FireWarden - <br /> 100-2, 01 — 50 on FireWarden -50. <br /> tln- 6999:b1 • 11/19/09 — Page 1 of 4 <br />