Laserfiche WebLink
• Direct Decade entry of address:, 01 — 99 on FireWarden- <br /> 3 I 1415 0 1 ADDRESS 0 1 100-2, 01 — 50 on FireWarden-50. <br /> s 13 / \2 �'\ 2 • LED flashes during normal operation. <br /> 3 1 12 � I / / 3 `— _ LOOP L / ) 43 • LED latches steady to indicate alarm on command from <br /> 1 10 \, /� / 5 control panel. <br /> 9 8 7 '6 ---J g 8 g 5 The NZM- 100(A) Interface Module is intended for use in intelli- <br /> TENS ONES gent, addressable systems, where the individual address of <br /> each module is selected using built-in rotary switches. This <br /> - - -- n module allows intelligent panels to interface and monitor two- <br /> t_ _ - <br /> wire conventional smoke detectors. It transmits the status (nor- <br /> mal, r l open, or alarm) of one full zone of conventional detectors <br /> W Q back to the control panel. All two -wire detectors being moni- <br /> - * OJ W „ Q toyed must be UL compatible with the module. <br /> 1 -4 ' ro NZM- 100(A) APPLICATIONS <br /> 1 Use the NZM- 100(A) to monitor a zone of two -wire smoke <br /> detectors. The monitored circuit may be wired as an NFPA <br /> Style B (Class B) or Style D (Class A) Initiating Device Circuit. <br /> I i A 3.9 K ohm End -of -Line Resistor (provided) terminates the <br /> The NMM- 100P(A) Mini Monitor Module can be installed in a end of the Style B or D (class B or A) circuit (maximum IDC <br /> single -gang junction directly behind the monitored unit. Its loop resistance is 25 ohms). Install ELR across terminals 8 <br /> small size and light weight allow it to be installed without rigid and 9 for Style D application. <br /> mounting. The NMM- 100P(A) is intended for use in intelligent, <br /> two -wire systems where the individual address of each module NZM- 100(A) OPERATION <br /> is selected using rotary switches. It provides a two -wire initiat- Each NZM- 100(A) uses one of the available module <br /> ing device circuit for normally- open- contact fire alarm and addresses on an SLC loop. It responds to regular polls from <br /> security devices. NMM- 100P(A) the control panel and reports its type and the status (open /nor- <br /> NMM- 100P(A) APPLICATIONS mal /short) of its Initiating Device Circuit (IDC). A flashing LED <br /> indicates that the module is in communication with the control <br /> Use to monitor a single device or a zone of four -wire smoke panel. The LED latches steady on alarm (subject to current <br /> detectors, manual fire alarm pull stations, waterflow devices, or limitations on the loop). <br /> other normally -open dry- contact devices. May also be used to <br /> monitor normally -open supervisory devices with special super NZM- 100(A) SPECIFICATIONS <br /> visory indication at the control panel. Monitored circuit/device Nominal operating voltage: 15 to 32 VDC. <br /> is wired as an NFPA Style B (Class B) Initiating Device Circuit. Maximum current draw: 5.1 mA (LED on). <br /> A 47K ohm End -of -Line Resistor (provided) terminates the cir- <br /> cuit. Maximum IDC wiring resistance: 25 ohms. <br /> NMM- 100P(A) OPERATION Average operating current: 300 pA, 1 communication and 1 <br /> Each NMM- 100P(A) uses one of the available module LED flash every 5 seconds, 3.9k eol. <br /> addresses on an SLC loop. It responds to regular polls from EOL resistance: 3.9K ohms. <br /> the control panel and reports its type and the status (open /nor- External supply voltage (between Terminals T3 and T4): <br /> mal /short) of its Initiating Device Circuit (IDC). DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms <br /> NMM- 100P(A) SPECIFICATIONS maximum. Current: 90 mA per module maximum. <br /> Nominal operating voltage: 15 to 32 VDC. Temperature range: 32 °F to 120 °F (0 °C to 49 °C). <br /> Average operating current: 350 pA, 1 communication every Humidity range: 10% to 93% noncondensing. <br /> 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> Shorted). 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x <br /> Maximum IDC wiring resistance: 40 ohms. 2.125" (5.398 cm) deep box. <br /> Maximum IDC Voltage: 11 Volts. NDM- 100(A) Dual Monitor Module <br /> Maximum IDC Current: 400 NA. The NDM- 100(A) Dual Monitor Module is intended for use in <br /> EOL resistance: 47K ohms. intelligent, two -wire systems. It provides two independent two - <br /> Temperature range: 32 °F to 120 °F (0 °C to 49 °C). wire initiating device circuits (IDCs) at two separate, consecutive <br /> addresses. It is capable of monitoring normally open contact fire <br /> Humidity range: 10% to 93% noncondensing. alarm and supervisory devices. The module has a single panel - <br /> Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x controlled LED. <br /> 0.65" (1.651 cm) deep. NOTE: The NDM- 100(A) provides two Style B (Class B) IDC cir- <br /> Wire length: 6' (15.24 cm) minimum. cuits ONLY. Style D (Class A) IDC circuits are NOT supported in <br /> any application. <br /> NZM- 100(A) Interface Module NDM- 100(A) SPECIFICATIONS <br /> • Supports compatible two -wire smoke detectors. Normal operating voltage range: 15 to 32 VDC. <br /> • Supervises IDC wiring and connection of external power Maximum current draw: 6.4 mA (LED on). <br /> source. Average operating current: 750 pA (LED flashing). <br /> • High noise (EMF /RFI) immunity. Maximum IDC wiring resistance: 1,500 ohms. <br /> • SEMS screws with clamping plates for ease of wiring. <br /> Page 2 of 4 — dn- 6999:b1 • 11/19/09 <br />