10-10030
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10030
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:00:57 AM
Creation date
3/22/2011 10:56:53 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYRHILLS FIRE DEPARTMENT
Building Department - Doc Type
Permit
Permit #
10-10030
Building Department - Name
ZEPHYRHILLS FIRE DEPARTMENT
Address
38410 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN- 60270:A <br /> C01224/111-MMCO <br /> ® NOT 1 F 1 E R <br /> Conventional Carbon Monoxide Detector/ <br /> Addressable Carbon Monoxode Detector Kit by Honeywell <br /> Intelligent/Addressable Devices <br /> General <br /> Carbon monoxide is an odorless, colorless, tasteless and <br /> highly toxic gas that is produced when fuels, such as wood, <br /> gasoline, charcoal and oil, are burned with insufficient air. The <br /> majority of residential and commercial fatalities caused from <br /> these fuels come from heating systems, power tools and <br /> charcoal grills. <br /> If carbon monoxide is detected, the C01224 will alert by <br /> sounding and flashing a temp -4 signal alarm. Protection is <br /> guaranteed 24/7 by a central station if connected to a panel <br /> with a digital alarm communicator. <br /> The C01224 is specifically designed for system operation. <br /> This means the detector is fully listed to UL Standard 2075, <br /> offering a code required trouble relay, which sends a sensor failure or end-of -life signal to the control panel and the central <br /> station, as well as SEMS -type terminal Phillips -head screws, <br /> which provide a quicker and more positive wiring connection ; <br /> and code required wiring supervision. Also, the C01224 offers <br /> low current draw, allowing more detectors to be connected to <br /> the panel without having to purchase a more expensive panel <br /> or an extra power supply. g <br /> Monitor modules are used to supervise a circuit of dry- contact <br /> input devices, such as the C01224 carbon monoxide detector. <br /> The FMM -101 is a miniature monitor module (a mere 1.3" <br /> (3.302 cm) H x 2.75" (6.985 cm) W x 0.5' (1.270 cm) D) used <br /> to supervise a Class B (Style B) circuit of dry- contact input <br /> devices. Its compact design allows the FMM -101 to often be Specifications <br /> mounted in a single -gang box behind the device it's <br /> monitoring. ARCHITECTS'/ENGINEERS' SPECIFICATIONS <br /> The N -MMCO addressable carbon monoxide detector kit Carbon monoxide detector shall be a System Sensor model <br /> number <br /> includes a C01224 carbon monoxide detector packaged Co, listed Tto he et for shall a <br /> for Gas and with <br /> together with a FMM -101 FlashScan monitor module. Detectors and d Sensors. The detector shall be equipped with a <br /> sounder and a trouble relay. The detector's base shall be able <br /> FlashScan® (U.S. Patent 5,539,389) is a communication to mount to a single -gang electrical box or direct (surface) <br /> protocol developed by NOTIFIER Engineering that greatly mount to the wall or ceiling. Wiring connections shall be made <br /> enhances the speed of communication between analog by means of SEMS screws. The detector shall provide dual <br /> intelligent devices. Intelligent devices communicate in a color LED indication, which blinks to indicate normal standby, <br /> grouped fashion. If one of the devices within the group has alarm, or end -of -life. When the sensor supervision is in a <br /> new information, the panel CPU stops the group poll and trouble condition, the detector shall send a trouble signal to the <br /> concentrates on single points. The net effect is response panel. When the detector gives a trouble or end -of -life signal, <br /> speed greater than five times that of other designs. the detector shall be replaced. <br /> Features (C01224) ELECTRICAL SPECIFICATIONS - C01224 <br /> • <br /> • Full compliance with UL 2075. Operating Voltage: 12/24 VDC <br /> • <br /> • A code required trouble relay. Audible Signal: 85 dB in alarm <br /> • <br /> • Wiring supervision with SEMS terminals. Standby Current: 20 mA <br /> • <br /> • A six -year end -of -life timer. Alarm Current: 40 mA (75 mA test) <br /> • 12/24 VDC. • Alarm Contact Ratings: 0.5 A @ 30 VDC <br /> • • A current draw of 20mA in standby and 40mA in alarm. Trouble Contact Ratings: 0.5 A 30 VDC <br /> • Versatile mounting for wall and ceiling. PHYSICAL SPECIFICATIONS - C01224 <br /> • Electrochemical sensing technology. • Size: 5.1 "L x 3.3 "W x 1.3 "H <br /> • Approximate Weight: 7 oz <br /> • Operating Temperature Range: 0 °C to 40 °C (32 °F to 104 °F) <br /> • Operating Humidity Range: 22% to 90% RH <br /> • Input Terminals: 14 to 22 AWG <br /> • Mounting: Single -gang backbox; surface mount to wall or <br /> ceiling. <br /> DN- 60270:A • 10/9/07 — Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.