Laserfiche WebLink
Operation Modes monitor normally -open supervisory devices with special <br /> supervisory indication at the control panel. Monitored circuit/ <br /> Operation Green LED Red LED Sounder device is wired as an NFPA Style B (Class B) Initiating Device <br /> Mode Circuit. A 47K ohm End -of -Line Resistor (provided) terminates <br /> Normal Blink 1 per _ <br /> the circuit. <br /> (standby) minute - NOTE: When used in conjunction with the C01224, the FMM -101 <br /> should be programmed as a supervisory device type and is not <br /> Alarm Blink in temp Sound in temp suitable for evacuation purposes. <br /> 4 pattern 4 pattern <br /> FMM -101 OPERATION <br /> Hush Feature Pushing the Test/Hush button will silence Each FMM -101 uses one of 159 available module addresses <br /> the sounder for 5 minutes. on an SLC loop. It responds to regular polls from the control <br /> Trouble Feature When the detector is in a trouble condi panel and reports its type and the status (open /normal /short) <br /> tion, it will send a trouble signal to the of its Initiating Device Circuit (IDC). <br /> panel via the trouble contact. FMM -101 SPECIFICATIONS <br /> End -of -Life Timer After the sensor inside the detector has Nominal operating voltage:15 to 32 VDC. <br /> reached the end of its useful life, a trou- <br /> ble signal will be sent to the panel. This Maximum operating current:375 pA. <br /> will indicate that it is time to replace the Maximum IDC wiring resistance1,500 ohms <br /> detector. An electrochemical carbon EOL resistance:47K ohms. <br /> monoxide detector life span is approxi- <br /> mately six years, and the detector must Temperature range:32 °F to 120 °F (0 °C to 49 °C). <br /> be replaced by the date marked on the Humidity range:10% to 93% noncondensing. <br /> inside of the product. Dimensions:1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x <br /> FMM -1O1 Mini Monitor Module 0.5• (1.270 cm) deep. <br /> Wire Iength:6" (15.24 cm) minimum. <br /> • Built -in type identification automatically identifies this device <br /> as a monitor module to the panel. Listings and Approvals <br /> • Powered directly by two -wire FACP. No additional power The listings and approvals below apply to the C01224. In <br /> required. <br /> some cases, certain modules may not be listed by certain <br /> • High noise (EMF /RFI) immunity. approval agencies, or listing may be in process. Consult <br /> • Tinned, stripped leads for ease of wiring. factory for latest listing status. <br /> • Direct -dial entry of address: 01 — 159 on FlashScan • UL Listed: E307195 <br /> systems, 01 — 99 on CLIP systems. <br /> °' — Ordering Information <br /> 3 14) 0 1 ADDRESS 0 1 i <br /> ° 2% ' z \2 <br /> « _2 Part Number Description <br /> 111 �%// )) 4 LOOP / C01224 12/24 volt, 4 -re system - monitored carbon <br /> / % 4 monoxide detector. <br /> 10V --, 5 /5 <br /> 9 8 ---- 7 6 9 g 7 6 N -MMCO Addressable carbon monoxide detector kit. <br /> TENS ONES Includes C01224 and FMM -101. <br /> n <br /> ■ <br /> OJ ,:j J U <br /> W <br /> W , 0 .' J cc <br /> r ' <br /> 1 <br /> The FMM -101 Mini Monitor Module can be installed in a <br /> single -gang junction directly behind the monitored unit. Its <br /> small size and light weight allow it to be installed without rigid <br /> mounting. The FMM -101 is intended for use in intelligent, two - <br /> wire systems where the individual address of each module is <br /> selected using rotary switches. It provides a two -wire initiating <br /> device circuit for normally- open- contact fire alarm and security <br /> devices. The FMM -101 can be used to replace MMX -101 <br /> module in existing systems. <br /> FMM -101 APPLICATIONS <br /> Use to monitor a single device or a zone of four -wire smoke <br /> detectors, manual fire alarm pull stations, waterflow devices, or <br /> other normally -open dry- contact devices. May also be used to <br /> Page 2 of 4 — DN- 60270:A • 10/9/07 <br />