• Real -time clock/calendar with automatic daylight savings • Maintenance / Presignal (yellow) <br /> control. • Disabled (yellow) <br /> • Detector sensitivity test capability (NFPA 72 compliant). • Battery Fault (yellow) <br /> • History file with 1,000 -event capacity. • Ground Fault (yellow) <br /> • Maintenance alert warns when smoke detector dust accu- <br /> mulation is excessive. KEYPAD CONTROLS <br /> • Automatic device type -code verification. • Acknowledge/Step <br /> • One person audible or silent walk test with walk -test log and • Alarm Silence <br /> printout. • Drill <br /> • Point trouble identification. • System Reset (lamp test) <br /> • Waterflow (nonsilenceable) selection per monitor point. • 16 -key alpha- numeric pad (similar to telephone keypad) <br /> • System alarm verification selection per detector point. • 4 cursor keys <br /> • PAS (Positive Alarm Sequence) and presignal delay per • Enter <br /> point (NFPA 72 compliant). <br /> NOTE: Only detectors may participate in PAS. Product Line Information <br /> SLC LOOP: NFW2 -100 Rev 2: FireWarden -100 -2 Rev 2 198 -point addres- <br /> • SLC can be configured for NFPA Style 4, 6, or 7 operation. sable Fire Alarm Control Panel, one SLC loop. Includes 80 <br /> • SLC supports up to 198 addressable devices per loop (99 character LCD display, single printed circuit board mounted on <br /> detectors and 99 monitor, control, or relay modules). chassis, and cabinet. 120 VAC operation. <br /> • SLC loop maximum length 10,000 ft. (3,000 m.). NFW2 -100R: Same as NFW2 -100 Rev 2, except in a red <br /> See installation manual for wire tables. backbox. <br /> NOTIFICATION APPLIANCE CIRCUITS (NACS): NFW2 -100E: Same as NFW2 -100 Rev 2, except with 240 <br /> VAC operation. <br /> • Four onboard NACs with additional NAC capability using 4XTM Reverse Polarity Transmitter Module: Provides <br /> output control modules (NC -100). The four Class B NACs supervised output for local energy municipal box transmitter, <br /> can be converted to two Class A NACs with NACKEY alarm, and trouble. <br /> (included). <br /> • Silence Inhibit and Auto Silence timer options. VFWARDEN -CD: Contains PS Tools Programming software <br /> Continuous, March Time, Temporal or California code for for Windowse -based PC computer (cable not included). <br /> • main circuit board NACs with two -stage capability. DP- 9692B: Optional dress panel for FireWarden -100 -2 Rev 2. <br /> • Selectable strobe synchronization per NAC. TR -CE -B: Trim Ring for semi -flush mounting. <br /> • 2.5 amps maximum per each NAC circuit. BB -26: Battery backbox, holds up to two 26 AH batteries and <br /> NOTE: Maximum 24VDC system power output is shared among CHG - 75. <br /> all NAC circuits and 24VDC special- application auxiliary power NFS Battery box, houses two 55 AH batteries. <br /> outputs. Total available output is 3.0 amps. Using the optional <br /> XRM - 248 transformer increases 24VDC output to 6.0 amps. CHG -75: Battery charger for lead -acid batteries with a rating <br /> of 25 to 75 AH. <br /> PROGRAMMING AND SOFTWARE: <br /> CHG -120: Remote battery charging system for lead -acid bat- <br /> • Autoprogram (learn mode) reduces installation time. teries with a rating of 55 to 120 AH. Requires additional NFS- <br /> • Custom English labels (per point) may be manually entered LBB for mounting. <br /> or selected from an internal library file. NOTE: CHG - 120 or CHG - 75 required for batteries larger than <br /> • Three Form -C relay outputs (two programmable). 18AH. <br /> • 99 software zones. BAT Series: Batteries, see data sheet DN -6933. <br /> • Continuous fire protection during online programming at the XRM- 24B(E): Optional transformer. Increases system power <br /> front panel. output to 6.0 amps. Use XRM -24BE with FireWarden- 100 -2E <br /> • Program Check automatically catches common errors not Rev 2. <br /> linked to any zone or input point. PRT /PK- CABLE: Cable printer /personal computer interface <br /> • OFFLINE PROGRAMMING: Create the entire program in cable; required for printer or for local upload /download pro - <br /> your office using a Windows® -based software package gramming. <br /> (NFW2 -100 requires PS -Tools Programming software, <br /> available on VFWARDEN -CD and www.magni- fire.com). PRN-6: UL listed compatible event printer. Uses tractor fed <br /> Upload/download system programming locally to the Fire- paper. <br /> Warden - 100 -2(E) Rev 2 in less than one minute. IPDACT2/2UD, IPDACT Internet Monitoring Module: <br /> • USB programming with standard Male -A to Male -B cable. Mounts in bottom of enclosure with optional mounting kit (PN <br /> IPBRKT). Connects to primary and secondary DACT tele- <br /> User interface phone output ports for internet communications over customer <br /> provided ethernet internet connection. Requires compatible <br /> LED INDICATORS Teldat VisorALARM Central Station Receiver. Can use DHCP <br /> • AC Power (green) or static IP. (See data sheet do - 60408 for more information.) <br /> • Fire Alarm (red) IPBRKT: Mounting kit for IPDACT -2/2UD in common enclo <br /> • Supervisory (yellow) sure. <br /> • Alarm Silenced (yellow) IPSPLT: Y- adaptor option allows connection of both panel <br /> dialer outputs to one IPDACT-2/2UD cable input. <br /> • System Trouble (yellow) <br /> Page 2 of 6 — DN- 60417:C • 12/17/2009 <br />