Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street: Permit Office: G 2 e-Pk`j 4( 15 <br /> City, State, Zip: TAMPA , FL , Permit Number: 1 0 ° f 7 0 <br /> Owner: LENNAR HOMES Jurisdiction: (Q (1 (PUT) <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft <br /> 2. Single family or multiple family Multi- family <br /> 3. Number of units, if multiple family 1 b. N/A R= it <br /> c. WA R= fY <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. N/A R= ft2 <br /> 7. Windows Description Area c. WA <br /> a. U- Factor: Dbl, U =0.60 119.64 ft2 R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: <br /> d. U- Factor: N/A ft <br /> SEER: 14 <br /> SHGC: 13. Heating systems <br /> e. U- Factor: N/A ft2 a. Electric Heat Pump Cap: 34 kBtu/hr <br /> SHGC: HSPF: 8.2 <br /> 8. Floor T es 14. Hot water systems <br /> YP Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft <br /> b. Raised Floor R =19.0 88.00 ft2 EF: 0.92 <br /> c. N/A R= ft2 b. Conservation features <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.100 Total As -Built Modified Loads: 30.62 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and THE 8::::4 <br /> this calculation are in compliance - the Florida Energy specifications covered by this ' y�� ' .. <br /> Code. calculation indicates compliance y i,,�' %�` a ms + <br /> PREPARED BY: ` V with the Florida Energy Code. ti :`iii .,, __.: ``` Before construction is completed ' r 6- . <br /> DATE: this building will be inspected for ` p4 ' <br /> 11, compliance with Section 553.908 <br /> 1 <br /> • <br /> hereby certify that •uildin 9. as desi• • compliance , � • ' Flor S tatutes. * t �' ' <br /> � <br /> with the Florida Energy Code . I I � <br /> CD O <br /> OWNER/AGENT . BUIL • <br /> DI • FFICIAL: <br /> DATE: tt I l'% � �% DATE: i L <br /> / <br /> - Compliance requires certificati • n by the air handler unit manufacturer that the air ha • ler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />