Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft <br /> 2. Single family or multiple family Multi- family <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c N/A R= ft <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. N/A R= ft= <br /> 7. Windows Description Area c N/A R= ft <br /> a. U- Factor. Dbl, U =0.60 119.64 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor. Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft <br /> 13. Heating systems <br /> SHGC: <br /> a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U- Factor: N/A ft= <br /> SHGC: HSPF: 8.2 <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge insulation R =0.0 1531.00 ft <br /> b. Raised Floor R =19.0 88.00 ft2 EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= fP <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.100 Total As -Built Modified Loads: 30.62 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and "' 37 <br /> this calculation are in compliance - 1 the Florida Energy specifications covered by this .:... p <br /> Code. calculation indicates compliance , h `• , " f , ' � „o'• <br /> V% ,, with the Florida Energy Code. :' Er n�„ a • t i ' p' <br /> PREPARED BY: R -- ____ ' I. J.-A_ _ Before construction is completed a .. + v: . <br /> DATE: this buildi will be in for ; a <br /> IP <br /> ' compliance with Section 553.908 '! <br /> certify that •uildin , as design -- ,• .• Florida Statutes. • ° , I hereb Y fY 9 9 mpliance with the Florida Energy Code. / , D w ,�0 . , OWNER/AGENT: MIK i1 )-••• <br /> BUILDING OFFICIAL: / ' <br /> DATE: /_� DATE: • <br /> 1 <br /> - Compliance requires certification by the air handler unit manufacturer that the air han ■ er enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />