Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types <br /> Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> • <br /> c. N/A R= ft2 <br /> 4. Number of Bedrooms 2 d. N/A <br /> R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types <br /> Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= ft <br /> a. U- Factor: Dbl, U =0.60 100.98 ft2 c. N/A R= ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgi, U =1.17 40.00 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft2 a. Central Unit <br /> SHGC: Cap: 34 kBtu/hr <br /> d. U- Factor: N/A ft2 SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U- Factor: N/A ft <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft2 a. Electric Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft2 <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ..• .. T HE S r,� <br /> this calculation are in compliance with the Florida Energy s pecifications covered by this '.' 0 , _ ... 4 \ Code. p <br /> p,a calculation indicates compliance <br /> ? '4$`�'� ., ,.� ; �' �, ` ` <br /> with the Florid E er gy Code. u,,, ti .... ' "` � PREPARED BY: 0 <br /> Before construction is completed r � .� .�, _� �.,, <br /> DATE: this building will be inspected for 6 C7 <br /> compliance with Section 553.908 1 0 ` l �� . a <br /> I hereby certify that this building, as design;'. • _ . mpliance Florida Statutes. * .i ' <br /> with the Florida Energy Code. / <br /> OWNER/AGENT: <br /> DATE: •/ BUILDING OFFICIAL: <br /> DATE: <br /> - Compliance requires certificatio by the air handler unit manufacturer that the air handler enclosure <br /> - <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />