Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: Permit Office: f <br /> City, State, Zip: TAMPA , FL , • G' Z��y ' <br /> Permit Number: j 0 7 <br /> Owner: LENNAR Jurisdiction: <br /> Design Location: FL, Tampa 6 I I (31) <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi- family a. Concrete Block - Int Insul, Exterior R=4.1 998.67 ft <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> c. WA R= ft= <br /> 4. Number of Bedrooms 3 d. WA <br /> R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types YPes Insulation Area <br /> 6. Conditioned floor area (ft2) 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> 7. Windows Description Area b. N/A R= ft2 <br /> ft <br /> a. U- Factor: Dbl, U =0.60 182.25 ft' c. N/A R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: N/A ft a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 285 ft <br /> SHGC: <br /> c. U-Factor: N/A = 12. Cooling systems <br /> ft a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: <br /> d. U- Factor: N/A ft2 SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft2 <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ftz a. Electric Cap: 40 gallons <br /> b. N/A R= ft2 <br /> b. Conservation features <br /> C. N/A R= EF: 0.92 <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.133 Total As -Built Modified Loads: 33.08 PASS <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and • ' ...;' <br /> this calculation are in compliance with the Florida Ene ' pfc T ST'9T ' •. <br /> Code. r9Y specifications covered by this - <br /> calculation indicates compliance ' ''''�f. " = 4, ' <br /> with the Florida Energy Code. ' : „ % ,,,' y •=.3/4=-.."0. . e <br /> . k,u: _us 0 O <br /> PREPARED B <br /> DATE: Before construction is completed r�'o <br /> this building will be inspected for ` 04 ` ilk O <br /> compliance with Section 553.908 ' • l �I� a <br /> o .r. <br /> I hereby certify that this building, as desig 3 , , in compliance Florida Statutes. . i�% ,..4 - tr <br /> with the Florida Energy Code. • .. y"t <br /> Op Nr '' . <br /> OWNER/AGENT: /1♦ / /lail:- BUILDING SIERC al-4 I ,i <br /> DATE: ,tiny --� <br /> ._�.ra, DATE: j <br /> - Compliance requires certification by the air handler unit manufacturer that the - it handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />