Laserfiche WebLink
• <br /> FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: <br /> City, State, Zip: TAMPA , FL , Permit Office: <br /> Owner. LENNAR Permit Number: <br /> Design Location: FL, Tampa Jurisdiction: <br /> 1. New construction or existing New (From Plans) 9. Wall Types <br /> 2. Single family or multiple family Insulation Area <br /> Y Multi family a. Concrete Block - Int Instil, Exterior R =4.1 998.67 ft <br /> b. N/A R= ft2 <br /> 3. Number of units, if multiple family 1 <br /> 4. Number of Bedrooms c. N/A R= ft2 <br /> 3 d. N/A <br /> R= ft: <br /> 5. Is this a worst case? Yes 10. Ceiling Types YPes Insulation Area <br /> 6. Conditioned floor area (ft2) 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> 7. Windows Description Area b. N/A R= ft2 <br /> a. U- Factor. DbI, U =0.60 182.25 ft2 c. N/A R= ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor. N/A ft a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: <br /> N/A ft2 <br /> c. U- Factor. 12. Cooling systems <br /> SHGC: a. Central Unit Cap: 28 kBtu/hr <br /> d. U- Factor. N/A ft2 SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft2 <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 a. Electric Cap: 40 gallons <br /> b. N/A R= <br /> b. Conservation features <br /> c. N/A R= EF: 0.92 <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.133 Total As -Built Modified Loads: 33.08 <br /> Total Baseline Loads: 40.16 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and . E <br /> this calculation are in compliance with the Florida Energy : ' pF <br /> Code. 9Y speaficetions covered by this y ; ,� fi AD <br /> ` calculation indicates compliance ''' ;` <br /> B with the Florida Code. <br /> Before �� ' :'; ����� <br /> !% l C <br /> PREPARED � is► Energy nm ; 4 . 0 <br /> DATE: e construction is completed "' Yom; <br /> this building will be inspected for 1 0 d <br /> compliance with Section 553.908 k o :r �' •` <br /> I hereby certify that this building, as desi • I ,)� • • mpliance Florida Statutes. ` ` :' t'" <br /> with the Florida Energy Code. I■ I <br /> OWNER/AGENT: BUILDING • <br /> _ \:, I <br /> DATE: <br /> ��� DATE: `� • Mar <br /> Ir <br /> - Compliance requires certification by the air handler unit manufacturer that the air andler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 1:29 PM <br /> EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />