Laserfiche WebLink
Schedule -10® /Schedule -40® <br /> When you specify Allied Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. <br /> Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality <br /> assurance you demand. Our Sch -10 (11/4"- 8 ") pipe and Sch -40 (1"- 21/2") pipe have passed the same thorough lab <br /> testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to <br /> ensure consistent quality. <br /> ,u� 40 �r,c� �,L, uu ,, <br /> ® Galvanized Pipe <br /> Schedule -10 /Schedule -40 product can be "hot -dip" NPS Nominal I D Wt. Wt. (H20 Filled) CRR <br /> galvanized to meet FM requirements for dry systems df` - 6u ... ''X <br /> in accordance with the zinc coating specifications of 1" 1.049 1 680 2.05 1 <br /> ASTM A-123. <br /> 11/4" 1.380 2.270 2.93 1 <br /> Superior Coating <br /> Our advanced formula mill coating offers a clean, 1' 1.610 2.720 3.61 1 <br /> durable surface. It is also paint -ready for custom . �°_ ' "',' "` , :hi ) ` i='' °" 537 <br /> color applications without special preparation. 2" 2.067 3.650 5.13 1 <br /> The internal surface of all Allied Tube & Conduit Fire 21/2» 2.469 5 7.86 1 <br /> Sprinkler pipe products up to 4.500" in diameter is X 65 62,7 6,6 11;73 <br /> coated with our new Antibacterial Formula, "ABFII ". <br /> In scientific laboratory tests, ABFII proved to have Sch - 10 Specifications <br /> superior resistance to microbial colonization of pipe NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR <br /> walls, thereby inhibiting or possibly preventing the _ ,,,,_ - L i ti :',' LL 'i , , ,m i P' ts i F, ' .i v`� d' , , ' <br /> onset of Microbiologically Influenced Corrosion 11/4" 1.442 1.810 2.525 7.0955 <br /> (MIC) upon installation and the first 25 flushes of -32 36 1'17- - -' ' 3,75 - <br /> the fire sprinkler system.* 11/2" 1.682 2.080 3.04 56570 <br /> 40 .4277 3x1 4.52 <br /> Cil American Made 2" 2.157 2.640 4.22 4.5827 <br /> Meets "Buy American" requirement and is available 50 54r9 as 6,28 <br /> through distributors in the USA, Canada, Mexico 2 2.635 3.530 5.89 3.5196 <br /> and Latin America. 65 66.9 5.3 8.77 "- <br /> 3" 3.260 4.330 7.94 2.5550 <br /> P Specifications & Approvals 80. 82.8 6.4 11.82 , <br /> Schedule -10 /Schedule - 40 pipe are in compliance 4" 4.260 5.610 11.78 1.6020 <br /> with the following: ASTM A -135, and NFPA 13. 94 1,42 83 17`53 <br /> All pipe products have a rated working pressure 5" 5.295 7.77 17.33 1 4874 <br /> of 300 psi maximum and also meet the stringent 125 134,5 11.56 25.80 <br /> requirements for the following applications and 6 " 6.357 9.290 23.03 1.0251 3 4 27 - <br /> tests: t 1 ;. ' " °= > 8 _ <br /> • Welded Outlets 8" 8.249 16.490 40.15 1 8365 <br /> • Hydrostatic Pressure 200 209:5 24,5 59.75 - <br /> • Side Wall Rupture ®c C) <br /> •PPNDVFD <br /> * See ABFII warranty <br /> ,mss . ". <br /> . _,, s., i _ - bit s FathhrO Harve it 60426 1 1 1351 Rd .: PA 19 1 2 52 N 2 � A2 85009 Sri <br />