Laserfiche WebLink
*aArwaw -a w!Ar <br />SPRINKLER HEAD <br />I sm <br />LEGEND <br />Q iY <br />TYPI: <br />_FlNISH <br />1T04JP <br />K <br />NPY <br />MF <br />MODEL. <br />SIN H <br />DESCRIPTION IAAX COVERAGE <br />O <br />12 <br />PENDENT <br />WHITE <br />155 <br />8.00 <br />3/4" <br />VIKING <br />M <br />VK-352 <br />RECESSED 1" DROP (E--1 ESCUTCH) / 130 SQ.FT, <br />12 = TOTAL QUANTITY FOR THIS TENANT. ALL HEADS ARE QUICK RESPONSE. <br />TO SPRINKLER <br />E .qa" <br />P DRAKE TO WIMP <br />ON MAH <br />N <br />Z. <br />INBPECYOfY97�$P6WtA1N <br />CHECK VALVE wiWO <br />4VALVEANOWES <br />- CONTROL VALVE w/ <br />QTAMPIEIIVMTCH <br />M <br />EXISTING RISER DETAIL <br />NOT TO SCALE <br />\S <br />a <br />GROOVE CHECK VALVE <br />WAIL MOUNT Z0 ` <br />STORTZ TYPE. <br />NOT TO SCALE <br />B.11 <br />.i <br />FIRE PROTECTION PLAN <br />SCALE: I /8" = I•_0•' <br />REMOVE EXIS77NG <br />M ' UPRIGHT SPRINKLER, <br />NEW I' 90 ELL NEW I" ARMOVER <br />TYPICAL I I ARMOVERS GREATER THAN <br />I I 24' SHALL HAVE HANGER. <br />EX1S17NG <br />I" SPRIG <br />EXISnNG 2" I <br />BRANCHLINE� NEW I" DROP <br />2x4 ACT CEILING <br />I* x 3/4" R. C. <br />01JARTER" POINT I <br />RETURN BEND IDETA� <br />NOT To SCALE <br />F PIPING LEGEND <br />=) <br />N <br />NEW PENDENT SPRINKLER <br />ON EXISTING PIPING USING <br />= 1 "' RETURN BEND. <br />cV I <br />-t <br />NI <br />1" NEW MECH TEE ON <br />( MT EXISTING PIPING. <br />_ (SIZED AS INDICATED) <br />Cv <br />2" 2" EXISTING PIPING AND <br />--- -� i -- SPRINKLER SHALL REMAIN. <br />EX (SIZED AS INDICATED) <br />BEAM CLAMP <br />ALL THREAD ROD (A.T,R.) ----_z <br />3/S A.T.R. 4 AND SMALLER <br />OPEN WES BAR JOIST <br />FOR 1" THROUGH 4" <br />ADJUSTABLE SWIVEL RING <br />Nm <br />HANG MAINS TO TOP CHORD <br />OF JOIST ONLY <br />BRANCHLINES MAY BE HUNG <br />FROM BOTTOM CHORD OF JOIST, <br />BEAM CLAMP <br />HANC'AER *1 DETAIL <br />NOT TO SCALE <br />OENER NOTES: <br />1. SPRINKLER SYSTEM SHALL COMPLY 1M111 THE 2002 EDITION OF NFPA 13. <br />2. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE. <br />REFER TO SPRINKLER HEAD LEGEND THIS SHEET. <br />3. SYSTEM 'TEST SHALL BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE MARSHAL PRIOR <br />TO ANY PORTION BEING CONCEALED. GIVE 48 HOURS NOTICE. <br />4. HANGERS TO BE PER DETAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN <br />ACCORDANCE MM 2002 NFPA 13 REQUIREMENTS. <br />5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. <br />6. 2" PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD --O-LETS OR <br />GROOVE -O -LETS. 1" PIPING SHALL BE THREADED SCHEDULE 40. 2" GRIDDEO PIPING <br />SHALL BE GROOVED SCHEDULE 10 WITH THREAD -O- -LETS. <br />7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING <br />UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL. <br />U) <br />2 <br />O <br />e5 <br />W <br />lY <br />4 <br />c7 <br />La. <br />O <br />m <br />ca <br />o <br />r- <br />CO <br />�wyy w <br />V <br />I� <br />EIRE PROTECTION <br />FLOOR PLAN <br />BLDG. PE RMIT <br />CAPSCO J08 <br />APPROVAL: <br />M B H <br />DRAM Vt <br />MBH <br />SCALE: <br />AS SHOWN <br />DATE. <br />10 12 10 <br />