Laserfiche WebLink
Dimensions , <br /> 6.8" dia. <br /> Application (173 mm) r <br /> Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing I <br /> " <br /> 1.0 <br /> codes require strobes to be used where ambient noise conditions (z 1 0" mm) <br /> exceed specified levels, where occupants use hearing protection, _ <br /> and in areas of public accommodation. Consult with your Authority ; <br /> o.so'(1s mm) <br /> Having Jurisdiction for details. — — — s <br /> All Genesis strobes exceed UL synchronization requirements <br /> (within 10 milliseconds over a two -hour period) when used with a <br /> synchronization source. Synchronization for multiple strobe lights <br /> in a single field of view is required. Light output (effective cd) <br /> MNEC Applications Percent of UL rating versus angle <br /> Genesis MNEC appliances bring the same high - performance life <br /> Percentage of rated output - <br /> safety features and unobtrusive design to mass notification applica- e e 40 a a e 20 70 100 110 ,ze 9°' tions. Available as standard units with clear or amber lenses with 80 90 <br /> optional ALERT markings, thy are ideal for applications that require l <br /> differentiation between life safety and MNEC signals. Units are also ` <br /> available (special order) with red, blue or green lenses. <br /> 7 5 j / 75" <br /> Installation: <br /> All models are intended for indoor applications only. Strobes <br /> mount to any flush North - American 4" square electrical box, 2'/ 45 <br /> (54 mm) deep. <br /> Genesis ceiling strobes simply unlatch and twist to open. This <br /> gains access to mounting screws and the selectable candela _15 - - - -. __ _ --- 15° <br /> switch. The shallow depth of Genesis devices leaves ample room Angle <br /> behind the signal for extra wiring. Once installed with the cover in Horizontal and vertical outputs reflect the same pattern. <br /> place, no mounting screws are visible. <br /> O . <br /> O - <br /> O ° o O• iii Field Configuration <br /> O o - o O' t . <br /> O• Depending on the model, Genesis ceiling Candela switch <br /> o <br /> O • � � • , ,� y ` • . speaker- strobes have mufti- candela output <br /> O - _ n !&! t the t esired be <br /> removed to change the output setting. 7 <br /> v The setting remains visible through a small Indicator <br /> window on the front of the device after the <br /> cover is closed. <br /> Wiring WARNING: Thesedeiceswit not operate withoutelectrical power. Asfiresfrequently <br /> Field wiring terminals accommodate #18 to #12 AWG (0.75 mm cause power interruptions,' we suggest you discuss further safeguards with your <br /> to 2.5 mm wiring. Strobes are interconnected with a single pair of low fire pfotection specialist. <br /> wires as shown below. These visible signal appliances' flash intensity may not be adequate to alert or <br /> awaken occupants in the protected area Research indicates that the intensity of <br /> strobe needed toawaken90%of sleeping personsis approximately 100 cd. Edwards <br /> + + recommends that strobes in sleeping rooms be 110 cd minimum. <br /> To listed " To next <br /> fire alarm device or <br /> control �j � «� 6 end of line <br /> panel device <br /> 85001 -0557 <br /> Page 2 of 4 Issue 6 <br />