My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-11161
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-11161
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2011 1:53:13 PM
Creation date
8/16/2011 1:52:12 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-11161
Building Department - Name
FMC MARKET SQUARE INC
Address
38051 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Current Draw <br /> UL 15 cd 1 30 cd 1 75 cd 95 cd 95 cd 1 115 cd j 150 cd ! 177 cd 4 <br /> Rating RMS RMS I RMS 1 RMS RMS RMS RMS RMS <br /> 16 Vdc 109 151 -- — <br /> 281 318 330 392 _ 502 565 <br /> 16 Vfwr 131 194 - ^ 379 437 432 518 643 693 — <br /> Typical 1 15 cd i 30 cd j 75 cd { RMS 95 cd 95 cd I 115 cd 150 cd 1 177 cd <br /> Current { RMS i RMS f RMS i RMS RMS � RMS �� RMS <br /> 16 Vdc 94 140 325 333 392 499 551 <br /> 20 Vdc 74 108 205 244 259 303 378 429 <br /> 24 Vdc 63 90 168 194 - -- 212 245 306 342 <br /> 33 Vdc 48 70 124 139 155 180 211 236 <br /> 16 Vfwr 126 187 368 403 _ 484 570 673 724 <br /> 20 Vfwr 108 156 281 333 380 438 537 604 <br /> 24 Vfwr 97 139 240 270 318 361 _ 434 484 <br /> 33 Vfwr 89 119 197 214 245 269 308 338 <br /> Notes and Comments <br /> 1. Current values are shown in mA. <br /> 2. UL nameplate rating is higher than typical current due to measurement methods and instruments used. <br /> 3. Edwards recommends using the typical current for system design including NAC and Power Supply loading. <br /> 4. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. <br /> 5. Fuses, circuit breakers and overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the <br /> current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. <br /> Specifications <br /> Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V -0 UL flammability rating. Red and white models <br /> available. <br /> Lens _ Optical Optical grade polycarbonate (clear). — - -- _ <br /> Mounting Flush mount to North American 4 -inch square electrical box, 2 -1/8 (54 mm) inches deep. No extension ring required. <br /> _ Suitable for indoor wall or ceiling applications. <br /> Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm to 2.5 mm wire size. <br /> Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. - -- <br /> Operating environment Indoor: 32 -120° F (0 -49° C) ambient temperature; 0 -93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for <br /> Agency listings /approvals standards CAN/ULC S526 -02 and CAN/ULC S524 -01. All models comply with ADA Code of Federal Regulation Chapter <br /> 28 Part 36 Final Rule. CSFM, MEA. FM pending. <br /> Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC -VM) and 95/115/150/177 cd (GC -VMH) <br /> Strobe operating voltage GC -VM series strobes: non - coded, filtered 16 -33 Vdc <br /> — — — or unfiltered 16 -33 Vdc FWR. <br /> GC -VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 <br /> Strobe flash rate milliseconds (or self- synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis <br /> Signal Master). Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same <br /> __ _ circuit. <br /> _ Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer <br /> Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire <br /> resistance. <br /> SIGA-CC1S, SIGA -MCC1 S, SIGA -CC2A, SIGA- MCC2A, G1M-RM -- ______ <br /> Synchronization Sources BPS6A, BPS10A, APS6A, APS10A, 064, i0500, Fireshield Plus 3, 5 and 10 zone. <br /> — __ ____ <br /> Add G1 M for G1 -CVM &G1 devices only. <br /> Page 3 of 4 <br /> . 85001 -0557 <br /> Issue 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.