SECTION IV — SYSTEM DESIGN <br /> UL EX. 3470 ULC CEx747 Page 4-5 <br /> 4 -1 -06 REV. 4 <br /> \,_,/ Plenum Protection ► Option 2: The 1W nozzle must be placed perpendicular, 8 -12 in. <br /> The R -102 system uses the 1W Nozzle (Part No. 419336) or the (20 -30 cm) from the face of the filter and angled to the <br /> • 1N Nozzle (Part No. 419335) for plenum protection. The 1W noz- center of the filter. The nozzle tip must be within 2 in. <br /> zle tip is stamped with 1W and the 1N nozzle tip is stamped with ( cm) from the perpendicular center line of the filter. <br /> i N, indicating they are one -flow nozzles and must be counted as See Figure 8. <br /> one flow number each. When protecting a plenum chamber, the 12 IN. (90 cm) <br /> entire chamber must be protected regardless of filter length. MA liko\ XIMUM <br /> 4 IN. <br /> VERTICAL PROTECTION — GENERAL (10 cm) <br /> • One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The , <br /> / i 8 I N . (20 cm) <br /> maximum distance from the end of the hood to the first and last ° I� <br /> nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any kb *`' <br /> additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) NOZZLE TIP °• <br /> apart down the entire length of the plenum. The plenum width must MUST BE WITHI <br /> THIS AREA <br /> ► not exceed 4 ft. (1.2 rn). (The 1W nozzle can be used on single or au . <br /> V bank filter arrangements.) See Figure 6. <br /> , •ir' <br /> 2FT.(.6m) <br /> MAXIMUM -► FIGURE 8 <br /> 000200 <br /> MAXIMUM 4 <br /> 4FT.(1.2m) �� \4FT.(1.2m) <br /> 2 Fr (.6 m) MAXIMUM • MAXIMUM HORIZONTAL PROTECTION — OPTION 1 <br /> MAXIMUM i 1N NOZZLE — PART NO. 419335 — SINGLE BANK PROTECTION <br /> � �/ One 1 N nozzle will rotect 10 li r , p nea f linear (3.1 m) of single filter bank <br /> �/ plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. <br /> 7 (5 to 10 cm) from the face of the filter, centered between the filter <br /> i height dimension, and aimed down the length. The nozzle must be <br /> ® % ,.� • positioned 0 -6 in. (0 -15 cm) from the end of the hood to the tip of the <br /> '" /�, I nozzle. See Figure 9. <br /> �. <br /> 2 - 4 IN. 10 FT (3.1 m) <br /> t FIGURE 6 (5 -10 cm) MAXIMUM <br /> 000,97 r <br /> ► When protecting plenums with the 1W nozzle, two options of cov- <br /> erage are available: <br /> ► Option 1: The 1W nozzle must be on the center line of the single 000201 40 or "V" bank filter and positioned within 1 -20 in. I <br /> (2.5 -51 cm) above the top edge of the filter. See <br /> Figure 7. \I <br /> 1 <br /> 20 IN. (51 cm) <br /> FIGURE 9 <br /> MAXIMUM `` 000202 <br /> 1 IN. (2.5 cm) <br /> MINIMUM <br /> :.::.::;. <br /> , <br /> 20 IN. (51 cm) <br /> i " 1 f <br /> MAXIMUM <br /> 1 IN. ( 2.5 cm <br /> MINIMUM <br /> FIGURE 7 <br /> 000199 <br />