Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett @fire.zephyrhi1Is. fl.us <br /> Plan Review #: 11 -005 <br /> Project: Interior Renovation <br /> Number of Pages: 16 <br /> January 20, 2011 <br /> I have received and reviewed the plans for the interior renovation located at 6020 Gall Blvd and <br /> will allow the plans to move forward providing changes are submitted with regards to the <br /> comments below. Either new plans can be submitted with an attached sheet outlining the changes <br /> made within the plans or a general comment sheet can be sent back in letter format indicating the <br /> changes therefore allowing attachment to the original submitted plans. This additional <br /> information will be required prior to receiving permit. By paying for permit contractor <br /> acknowledges to comply with the items below. Should anyone have any questions, please do not <br /> hesitate to contact the Fire Marshal's office. <br /> 1. Page CR, indicates no fire alarm or fire sprinkler system. This building has both and <br /> will continue to have both. <br /> 2. Page G -1, this project must also comply with the Florida Fire Prevention Code. The <br /> Florida Fire Prevention Code will supersede the Florida Building Code in all areas <br /> dealing with life safety. <br /> 3. Page G -1, Rated walls shall be stenciled in accordance to NFPA and/or the FFPC. <br /> Florida does not use the I.B.C. or North Carolina Building Code. <br /> 4. Page G -1, during demo, fire safety practices shall be in accordance to FFPC and/or <br /> NFPA 1. If either of the fire protection systems (fire alarm/fire sprinkler system) <br /> are down, this authority shall be notified or fire watch may need to be established in <br /> the applicable buildings tied to these systems. Fire watch will be provided by this <br /> agency at an additional cost. <br /> 5. Page A -1 & A -2, fire wall shall be inspected by the Fire Marshal and not the <br /> Building Inspector. <br /> 6. Page A -3, there is a notation about fire sprinkler plans. Fire sprinkler plans will <br /> require to be turned in separately with all calculations, cut sheets on all components <br /> used and details. Plans shall show how it is now and what the finish project will be. <br /> This is required to obtain a fire sprinkler permit. If there is a backflow preventor for <br /> this system, it shall have tamper switches installed. The sprinkler system currently <br /> covers two other tenants. System shall be modified by installing additional flow <br /> switches so that when heads activate in it will indicate where they activated in the <br /> fire alarm panel. <br /> 7. Page E -1, penetrations through any fire rated wall will be UL listed. <br /> 8. Page E -1, address the outside electric panels. <br /> 9. Page E -3, Fire alarm plans will be required to be turned in separately with all <br /> calculations, cut sheets on all devices used and details. Plans will show how it is <br /> now and what the finish project will be. This is required to obtain a fire alarm <br /> permit. Panel shall be addressable and devices labeled back to the panel. Strobes <br />