My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10904
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10904
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2012 11:51:30 AM
Creation date
2/7/2012 11:51:23 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYRHILLS COLONY
Building Department - Doc Type
Permit
Permit #
10-10904
Building Department - Name
GRAND RESERVE APARTMENTS LTD
Address
38576 VALLEY OAKS CR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 2 <br /> 12. Check UL305 design for a 1 hour wall. The design does not show furring <br /> strips being used and the architects design does. <br /> 13. If rated electrical boxes are used, documentation shall be provided to this <br /> office prior to use. <br /> 14. When taping and mudding fire rated walls and ceiling use rated mud and <br /> tape. <br /> 15. Label all access panels for what they are. Ensure all panels meet the rating. <br /> 16. Labet all mechanical/electric rooms as such. <br /> 17. Label FACP room. <br /> 18. A knox box will be required. An application can be obtained from this office. <br /> 19. All penetrations through a fire rating shall be in accordance to the method <br /> provided in the plans. <br /> 20. Emergency instructions shall be provided annually to each dwelling unit to <br /> indicate location of a(arms, egress paths, actions to be taken both with <br /> response to fire or sounding of the alarm. <br /> 21. Smoke detectors in each unit shall be tested monthly and batteries changed <br /> semi-annually. A log shall be kept. <br /> 22. Extinguisher log also shall be kept for individual units. <br /> 23. A written record shall be kept of monthly operation of the firefighters <br /> emergency operation in the elevators. <br /> 24. Elevators shall comply with ASME A 17.1 <br /> 25. The following shall be tested: <br /> A. Fire Alarm — annually <br /> B. Sprinklers and standpipes — quarterly <br /> C. Backflow assembly — annually <br /> D. Fire extinguishers — annually <br /> E. Elevator — annually <br /> F. Smoke detectors — monthly (tested) semi-annually (batteries) <br /> - G. Hood Suppression — semi-annually <br /> H. Hood cleaning — semi-annually <br /> NOTE: Revisions should be specific to comments and addressed on letterhead. <br />
The URL can be used to link to this page
Your browser does not support the video tag.