Laserfiche WebLink
FORM 1100A-0$ <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential PerFormance Method A <br /> Project Name: 6 - s 01 TH Builder Name: LENNAR HOMES <br /> Street: T'h BfR�.y ��,F Permit Office: C� �- ���oyYiCt/i«s <br /> City, State, Zip: ZEPHYRHILLS , FL , 3 3 S y Permit Number: j("�Qb <br /> Owner• LENNAR HOMES �� �� Jurisdiction: b� ���b <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types (1810.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Exterior R=4.1 1064.00 ft= <br /> b. Concrete Block - Int Insul, Common R=4 1 420.00 ftz <br /> 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11 0 326.67 ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types (1517.0 sqft.) Insulation Area <br /> 6. Conditioned floor area (ft 1517 a. Under Attic (Vented) R=30.0 1517.00 ft' <br /> b. N/A R= ftz <br /> 7. Windows(208.0 sqft.) Description Area c. N/A R= ft <br /> a. U-Factor: Dbl, U=0.60 208.00 ft= <br /> SHGC: SHGC=0.32 11 Ducts <br /> b. U-Factor: N/A g= a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 340 ft <br /> SHGC• 12. Cooling systems <br /> c. U-Factor: N/A ftz a. Central Unit Cap: 30.0 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U-Factor: N/A ft 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 30.0 kBtu/hr <br /> e. U-Factor: N/A ft2 HSPF.8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types (1517.0 sqft.) Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1517.00 ft2 EF: 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ftz None <br /> 15. Credits Pstat <br /> Glass/FloorArea: 0.137 Total As-Built Modified Loads: 32.13 pASS <br /> Total Baseline Loads: 38.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'��Y� ST.�?,�; , <br /> this calculation are in compliance ith the Florida Energy specifications covered by this ' 4,� ��,, ��, r <br /> Code. calculation indicates compliance ` f �'�u,,�,,, �; _,.��°,�� � � <br /> with the Florida Energy Code. ti��;;;,�'�-:, •`:•:_::�:�'': O <br /> PREPARED BY: Before construction is completed - w- ��� "r �• <br /> . � ��,�,. <br /> DATE: this building will be inspected for -� ` [�''I_ „�_ .,3. <br /> :, compliance with Section 553.908 � * �� X #� :� � <br /> I hereby certify that t' ilding, as designe is in compliance Florida Statutes. r`' :����4 . <br /> with the Florida Energy Code. � � DU WG'T� •' <br /> � <br /> OWNER/AGENT:- � BUILDING ��I�� <br /> DATE: DATE: L <br /> - Compliance requires certification y he air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-sealed in accordance with N1110.A.3. <br /> 2/1/2011 4�11 PM EnergyGauge� USA - FlaRes2008 Page 1 of 5 <br />