My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11706
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11706
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2012 11:00:37 AM
Creation date
2/8/2012 11:00:32 AM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-11706
Building Department - Name
EILAND PARK TOWNHOMES ASSOC INC
Address
6359 TIMBERLY LN AREA B #140
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 1100A-08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1501 TH Buiider Name: LENNAR HOMES <br /> Street: T nt�F+tt-f/ Lw�vF Permit Office: �'tfc/ s� 2E�.i�c��Q,y/tW <br /> City, State, Zip: ZEPHYRHILLS , FL , 33Syo Permit Number: J � <br /> Owner: LENNAR HOMES �,,,o T(�-�'0 Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1 New construction or existing New (From Plans) 9. Wall Types (1810.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Exterior R=4 1 1064 00 ftz <br /> b. Concrete Block - Int Insul, Common R=4 1 420.00 ft' <br /> 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11 0 326.67 ftZ <br /> 4 Number of Bedrooms 3 d. N/A R= ft <br /> 5 Is this a worst case? Yes 10. Ceiling Types (1517 0 sqft.) Insulation Area <br /> 6. Conditioned floor area (ftz) 1517 a. Under Attic (Vented) R=30.0 1517.00 ftz <br /> b. N/A R= ftz <br /> 7. Windows(208.0 sqft.) Description Area c. N/A R= ft <br /> a. U-Factor• Dbl, U=0.60 208.00 ft <br /> SHGC: SHGC=0.32 11. Ducts <br /> b. U-Factor• N/A ftz a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 340 ftz <br /> SHGC: 12. Cooling systems <br /> c. U-Factor• N/A ftz a. Central Unit Cap: 30.0 kBtu/hr <br /> SHGC• SEER: 14 <br /> d. U-Factor N/A ftz 13. Heating systems <br /> SHGC� a. Electric Heat Pump Cap: 30.0 kBtu/hr <br /> e. U-Factor• N/A ft2 HSPF 8.2 <br /> SHGC: <br /> 14 Hot water systems <br /> 8 Floor Types (1517.0 sqft.) Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1517.00 ftz EF 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ftz None <br /> 15 Credits Pstat <br /> Glass/Floor Area: 0.137 Total As-Built Modified Loads: 32.13 pASS <br /> Total Baseline Loads: 38.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ''��tTE STq�, . <br /> this calculation are in compliance ith the Florida Energy specifications covered by this �.� __ �°�,� <br /> Code. calculation indicates compliance �,,���„ T� �=' �`� <br /> o �' <br /> wi t h t he F lori da Energy Co de. � 7�,, •::::'��°°,��- „ O <br /> PREPARED BY: Before construction is completed ,w�� - -����i ;�� <br /> �_"s. ' v <br /> DATE: this building will be inspected for � � �_� �� <br /> compliance with Section 553.908 , , � ° <br /> I hereby certify that t� ' ilding, as designe in compliance Florida Statutes. • r� ��"g``' .. <br /> with the Florida Energy Code. •, Op y` ��,�� ,. <br /> OWNER/AGENT: BUILDING OFFICIAL: — <br /> DATE: DATE: <br /> � <br /> - Compliance requires certification b the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-sealed in accordance with N1110.A.3. <br /> 2!1/2011 4.11 PM EnergyGauge� USA - FlaRes2008 Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.