My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11786
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 9:01:27 AM
Creation date
2/9/2012 9:00:05 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11786
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7326 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> SYSTEM SPECIFICATIONS <br /> System Capacity (noncondensing) at 32°C t 2°C (90°F t 3°F). However, the <br /> useful life of the system's standby batteries and the e�ectronic <br /> • Intelligent Signalling Line Circuits .......................................1 components may be adversely affected by extreme tempera- <br /> • Addressable device capacity ................................. .. .......50 ture ranges and humidity. Therefore, it is recommended that <br /> • Programmable software zones ......... ...............................20 this system and its peripherals be installed in an environment <br /> • Annunciators ............. ............................. .........................8 with a normal room temperature of 15 — 27°C/60 — 80°F. <br /> Electrical Specifications NFPA Standards <br /> AC Power: FireWarden-50: 120 VAC, 60 Hz, 3.0 A. FireWar- The FireWarden-50 complies with the following NFPA 72 Fire <br /> den-50E: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG Alarm Systems requirements: <br /> (2.00 mm2) with 600 V insulation. Nonpower-limited, super- — LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> vised. Supervisory). <br /> Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger — AUXILIARY (Automatic, Manual and Watertlow) (requires <br /> Capaciry: 7-18 AH (FireWarden-50 cabinet holds maximum of 4XTM). <br /> two 18 AH batteries.) — REMOTE STATION (Automatic, Manual and Waterflow) <br /> Communication Loop: Supervised and power-limited. (Where a DACT is not accepted, the alarm, trouble and <br /> supervisory relays may be connected to UL 864 listed <br /> Notification Appliance Circuits: Terminal Block provides transmitters. For reverse polarity signaling of alarm and <br /> connections tor two NACs, Style Y(Class B) or. Style Z(Class trouble, 4XTM is required.) <br /> A). Special Application power. Power-limited, supervised cir- <br /> cuitry. Maximum signaling current per circuit: 2.5 A. End-of- — PROPRIETARY (Automatic, Manual and Waterflow). <br /> Line Resistor: 4.7 kohm,'/z watt (P/N 71252 UL listed) for Style — CENTRAL STATION (Automatic, Manual and Waterflow, <br /> Y(Class B) NAC. Refer to the NOTIFIER Device Compatibility and Sprinkler Supervised). <br /> Documentfor listed compatible devices. — OT, PSDN (Other Technologies, Packet-switched Data <br /> Two Programmable Relays and One Ftxed Trouble Relay: Network) <br /> Contact rating: 2.0 A� 30 VDC (resistive), 0.5 A C� 30 VAC <br /> (resistive). Form relays, nonpower r,or,super��sed. Agency Listings and Approvals <br /> The listings and approvals below apply to the basic FireWar- <br /> Cabinet Specifications den control panel. In some cases, certain modules may not <br /> Door: 1926' (48.92 cm.) high x 16.82' (42.73 cm.) wide x be listed by certain approval agencies, or listing may be in pro- <br /> 0.72° (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x cess. Consult factory for latest listing status. <br /> 16.65" (42.29 cm.) wide x 5.25` (13.34 cm.) deep. Trim Rtng • UL: S635 <br /> (TR-CE/B): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. . FM approved <br /> Shipping Specifications • CSFM: 7165-0028:239 <br /> • MEA: 442-06-E Vol. 2 <br /> Weight: 26.9 Ibs. (1220 kg.) Dtmensions: 20.00" (50.80 cm.) NOTE: See DN-60446 for ULC-listed model. <br /> high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. <br /> Temperature and Numidity Ranges <br /> This system meets NFPA requirements for operation at 0— <br /> 49°C/32 — 120°F and at a relative humidity 93% t 2% RH <br /> NOTIFIER�, FireWarden�, and System Sensor� are registered <br /> trademarks of Honeywell Intemational Inc. Microsofi� and Windows� are <br /> registered trademarks of the Microsoft Corporation. <br /> �YL010 by Honeywell International Inc. All rights reserved. Unauthorized use <br /> of this document is strictly prohibited. <br /> '�O � This document is not fntended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> g�p�� g� All specifications are subject to change without notice. <br /> QUALITY SYSTEMS MadeintheU.S.A. <br /> For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. <br /> www.notifter.com <br /> Page 4 of 4— DN-7102:D • 6/17/2010 <br /> P. 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.