Laserfiche WebLink
DN-7001:C1 •Ai-380 <br /> NOT-BG 12LX ('� N 4T 1 F 1 E R <br /> Addressable Manual Pull Station � <br /> For FireWarden Series Panels by Honeywell <br /> . <br /> General <br /> x��:��� <br /> The Notifier NOT-BG12LX is a state-of-the-art, dual-action i �� <br /> (i.e., requires two motions to activate the station) pull station <br /> that includes an addressable interface for FireWarden series ~� <br /> intelligent control panels, and the NSP-25 panel. Because the <br /> NOT-BG12LX is addressable, the control panel can display the <br /> exact location of the activated manual station. This leads fire i <br /> personnel quickly to the location of the alarm. i <br /> ,� <br /> Features � � � <br /> A <br /> • Maintenance personnel can open station for inspection and <br /> address setting without causing an alarm condition. � <br /> • Built-in bicolor LED, which is visible through the handle of � <br /> the station, flashes in normal operation and latches steady <br /> red when in alarm. <br /> • Handle latches in down position and the word "ACTIVATED" <br /> appears to clearly indicate the station has been operated. $ <br /> • Captive screw terminals wire-ready for easy connection to � <br /> SLC loop (accepts up to 12 AWG/3.25 mm wire). <br /> • Can be surface mounted (with SB-10 or SB-I/O) or semi- <br /> flush mounted. Semi-flush mount to a standard single- <br /> gang, double-gang, or 4" (10.16 cm) square electrical box. <br /> • Smooth dual design. The NOT <br /> • Meets ADAAG controls and operating mechanisms guide- Add�BS38bl@ Ma1fU81 PUII StatiOn <br /> lines (Section 4.1.3[13]); meets ADA requirement for 5 Ib. <br /> maximum activation force. <br /> • Highly visible. The BG12TR is usually needed tor semi-flush mounting with 4' <br /> • Attractive shape and textured finish. (10.16 cm) or double-gang boxes (not with single-gang boxes). <br /> • Key reset. O peration <br /> • Includes Braille text on station handle. <br /> • Optional trim ring (BG12TR). Pushing in, then pulling down on the handle causes it to latch <br /> in the down/activated position. Once latched, the word "ACTI- <br /> • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yeilow) appears at the top of the handle, <br /> Boxes. while a portion of the handle protrudes from the bottom of the <br /> station. To reset the station, simply unlock the station with the <br /> Construction key and pull the door open. This action resets the handle; clos- <br /> Shell, door, and handle are molded of durabie polycarbonate ing the door automaticaliy resets the switch. <br /> material with a textured finish. Each manual station, on command from the control panel, <br /> sends data to the panel representing the state of the manual <br /> Specifications switch. Two rotary decimal switches allow address settings <br /> (1 — 99 on NFW2-100/NFW2-100C, 1— 50 for NFVN-50/NFW- <br /> • Shipping Weight: 9.6 oz. (272.15 g) 50C). <br /> • Normal operating voltage: 24 VDC. <br /> • Maximum SLC loop voltage 2s.o voc. Architectural/Engineering <br /> • Maximum SLC loop current: �A. S pecifications <br /> • Temperature Range: 32°F to 120°F (0°C to 49°C) Manual Fire Alarm Stations shall be non-coded, with a key- <br /> • Relative Humidity: 10% to 93% (noncondensing) operated reset lock in order that they may be tested, and so <br /> • For use indoors in a dry locatton designed that after actual Emergency Operation, they cannot <br /> be restored to normal except by use of a key. An operated sta- <br /> Installation tion shall automatically condition itself so as to be visually <br /> detected as activated. Manual stations shall be constructed of <br /> The NOT-BG12LX will mount semi-flush into a single-gang, red-colored polycarbonate material with clearly visible operat- <br /> double-gang, or standard 4' (10.16 cm) square electricai outlet �ng instructions provided on the cover. The word FIRE shall <br /> box, or will surtace mount to the model SB-10 or SB-I/O sur- appear on the front of the stations in white letters, 1.00 inches <br /> face backbox. If the NOT-BG12LX is being semi-flush �2•54 cm) or larger. Stations shali be suitable for surface <br /> mounted, then the optional trim ring (BG12TR) may be used. mounting on matching backbox SB-10 or SB-I/O; or semi-flush <br /> mounting on a standard single-gang, double-gang, or 4' <br /> (10.16 cm) square electrical box, and shall be installed within <br /> DN-7001:C1 • 8/i 6/10 — Page 1 of 2 <br /> P. 5 <br />