Laserfiche WebLink
360 pounds can be obtained. Please contact Carlisle's at those locations where Fastening Plates are located <br /> Systems Design and Review Group sheet sizing and (along length of the membrane) and a minimum of Z" at <br /> fastener spacing. end roll sections (width of the membrane). <br /> 6. Cementitious W ood Fiber and Gypsum - The Cazlisle 4 Hot air weld the membrane sheets a minimum of 1-1 /2" <br /> HP-N'TB Fastener is required with a minimum pullout with an Automatic Hot Air Welding Machine. <br /> of 300 pounds. <br /> 5. Membrane that has been exposed to the elements for <br /> 3.03 SUBSTRATE PREPARATION approximately 7 days must be prepared with Weathered <br /> Membrane Cleaner. Wipe the surface where Weathered <br /> A. On retrofit-recover projects, cut and remove wet insulaYion, Membrane Cleaner has been applied with a clean, dry <br /> as identified by specifier, and fill all voids with new HP Splice Wipe or other white rag to remove cleaner <br /> insulation so it is relatively flush with existing surface. residue prior to hot air welding. <br /> B. For all projects, substrate must be even without noticeable C. Additional Membrane Securemeot <br /> high spots or depressions, and must be free of accumulated <br /> water, ice or snow. The membrane must be secwed at the perimeter of each roof <br /> level, roof section, expansion joint, curb, skylight, interior <br /> C. Clear the substrate of debris and foreign materiaL Fresh wall, penthouse, etc., at any angle change which exceeds 2" <br /> bitumen based roof cement must be removed or concealed. in one horizontai foot and at all other penetrations in <br /> accordance with Carlisle's Details published with Carlisle's <br /> 3.04 INSTALLATION Specifications. <br /> Refer to the applicable Material Safety Data Sheets and Technical D. Membrane FiAShing <br /> Data Bulletins for applicable cautions and warnings. <br /> l. Fiash all walls and curbs with Sure-Weld reinforced <br /> A. Insulallon Attac6ment membrane. Non-Reinforced membrane shall be limited <br /> to inside and outside comers, field fabricated pipe seals, <br /> l Carlisle Insulation sha(1 be mechanically fastened to ihe scuppers and Sealant Pockets where the use of pre- <br /> roof deck as follows: molded accessories are not practica(. Terminate the <br /> flashing in accordance with an appropriate Carlisle SW- <br /> a. For HP Recovery Board or minimum 1-I/2" thick 9 Termination Detail. <br /> Polyisocyanurate, a minimum of 5 fasteners and <br /> plates per 4' x 8' boazd are required. 2. On vertical surfaces, such as walls, curbs and pipes, <br /> Bonding Adhesive is not required when the flashing <br /> b. For Polyisocyanurate less than 1-1/2" thick or height is 12" or less and the membrane is terminated <br /> Foamulaz or DOW Eactruded Polystyrene, any under a metal counterflashing (nailed). When a coping <br /> thickness, a minimum of 6 fastenets and plates per or termination baz is used for vertical terminations, <br /> 4' x 8' board are required. Bonding Adhesive may be eliminated for flashing <br /> heights 18" or less. <br /> Note: Extruded polystyrene insulation is for <br /> use directly under white Sure-Weld E. Other Related Work <br /> membrane only <br /> 1. Walkways are required for all traffic concentration <br /> c. Insulation boards 4' x 4', regardless of thiclmess, points (i.e., roof hatches, access doors, rooftop ladders, <br /> must be fastened at the minimutn rate of 1 fastener etc.), regardless oftraflic frequency. Walkways are also <br /> and plate every 4 square feet. required if regular maintenance (once a month or more) <br /> is necessary to service rooftop equipment. Walkways <br /> 2. Carlisle Piranha Plates, Seam Fastening Plates (2" are considered a maintenance item and are excluded <br /> diameter) or InsWation Fastening Plates (3" diameter) from the Cazlisle Warranty <br /> must be used with appropriafe Carlisle Fastener for <br /> insulation attachment. 2. Sure-Weld Heat Weldable Walkway Rolls are required <br /> when walkway pads are specified and are heat welded to <br /> B. Membrane Placement, Attachment and Hot Air Welding the Sure-Weld Membrane. <br /> 1 A minimum of one perimeter sheet shall be installed at When concrete pavers are used, they shall be loose laid <br /> edges of each roof level and 12', 10' or 8' wide and installed in conjunction with a slip sheet of <br /> membrane shall be installed in the field of the roof. reinforced membrane or two layers of HP Protective <br /> Mat. Concrete pavers are not recommended when the <br /> 2. Membrane sheets shall be mechanically fastened with roof slope is greater than 2" per i horizontal foot. <br /> the appropriate Carlisle FastenedFastening Plate spaced <br /> 6" to 12" on center, depending on project criteria, within Carlisle Interlocking PaversTM, 24" X 24" X 2", <br /> the membrane splice. Refer to the "Design Criteria" weighing approximately 6 pounds per square foot may <br /> section for required number of perimeter membrane be loose laid directly over the membrane. Installation <br /> sheets and fastener spacing. instniction sheets are available from Carlisle. <br /> 3. Overlap adjacent membrane sheets approximately 5-1/2" <br /> 3 <br /> 600319 SWMF Guide - 2/2006 <br />