Laserfiche WebLink
insulation on a skid and completely cover with a breathable <br /> material such as tazp or canvas. If the insulation is 2.02 MEMBRANE <br /> lightweight, it should be weighted to prevent possible wind <br /> damage. Sure-Weld white, gray or tan 45, 60, 72, 80-mil thick reinforced <br /> T'hermoplastic Polyolefin (TPO) membrane is used for this system. <br /> 1.05 JOB CONDITIONS Field membrane sheets aze 12', 10' or 8' wide by 100' long based <br /> on project conditions. Perimeter sheets are 6' wide (used with 12' <br /> A. This system must not be applied on projects where the slope field sheets), 5' wide (used with 10' field sheets} or 4' wide (used <br /> exceeds 18" in one horizontal foot. When the roof slope with 8' field sheets). For physical propedies of inembrane, refer to <br /> exceeds 5" per horizontal foot, use of an automatic welding page 4 <br /> machine may be more difficult. A hand held welder should <br /> be specified. 2.03 RELAT'ED MATERIALS <br /> B. Existing roofing material must be investigated by the Sure-Weld Non-Reinforced or Reinforced Flashing, Bonding <br /> specifier and all wet material must be removed. Adhesive, Cut Edge Sealant, Water Cut-Off Mastic, PT 304 <br /> Sealant, EP-95 Spicing Cement, Weathered Membrane Cleaner, <br /> C Existing phenolic insulation and sprayed-in-place urethane Molded Pocket Sealant, Heat Weldable Walkway Pads, Pre- <br /> roofs must be removed prior to installation of this system. Molded Inside/Outside Comers, Pipe Flashings, Curb Wraps and <br /> Sealant Pockets. <br /> D. The use of a vapor retarder to protect insulation and reduce <br /> moisture accumulation within an insulated assembly should PART III EXECiTI'ION <br /> be investigated by the specifier Consult the publications by 3A1 GENERAL <br /> ASHRAE (American Society of Heating, Refrigerating and <br /> Air-CondiGoning Engineers, Inc.) and NRCA (National A. When feasible, begin the application at the highest point of <br /> Roofing Contracwrs Association) for specific infonnation. the highest roof level and work to the lowest point to prevent <br /> moisture infiltration and to minimize conshvction traffic on <br /> E. Coordination between trades is essential to avoid unnecessary completed secUons. This will include complelion of all <br /> traffic over sections of the roof and to prevent damage to the flashings, terminations and daily seals. <br /> membrane roofmg system. <br /> B. Follow criteria outlined in the "Design Criteria" section to <br /> 1.06 WARRANI`Y prepare the roof deck or the existing substrate prior to the <br /> application of the new roofing system. <br /> All warranties are availabie for wmmercial pmjects only <br /> 3.02 ROOF DECK CRITERIA <br /> A. A 5 or 10 year Membrane System Warranty, with a wind <br /> speed wverage of up to 55 mph is available for a charge. A. Proper substrate shall be provided by the buitding owner <br /> The structure shall be sufficient to withstand normal <br /> B. A 10 or 15-year Total Roofing System Warranty is conshuction loads and live loads. <br /> available for a charge on commercial pmjects. Projects will <br /> receive a maximum peak gust wind speed coverage up to 55 B. Defects in the roof deck must be reported and documented to <br /> mph unless prior review is performed by Carlisle regarding the specifier, general contractor and building owner for <br /> an e�ended wind speed coverage. assessment. The Carlisle Authorized Applicator shall not <br /> proceed with installation unless defects are corrected. <br /> The 15-year Warrxety is not availabk for projects with <br /> cementitious wood fiber or gypsum decks. C Acceptable decks and the applicable Cazlisle Fasteners: <br /> Note: Due to various wind uplift coverages available, 1 Steel, 22 gauge or heavier - Carlisie HP-X <br /> these projects must be reviewed by Carlisle prior to Fasteners/Piranha Plates or HP-Xtra Fasteners/Piranha <br /> bid, prefe►rably in design phase, to determine Xtra Plates are required with a minimum pultout of 500 <br /> system enhancements that may be applicable. pounds per fastener <br /> C A 20-yeaz Total System Wan-anty is available for a charge 2. Lightweight Insulating Concrete over steel - Carlisle <br /> for projects utilizing minimum 60-mil thick Sure-Weld HP-X Fasteners/Piranha Plates are required with a <br /> membrane and incorporating additional design minimum pullout of 360 pounds per fastener (into steel <br /> enhancements as outlined in "Attachment IV", 20-Year deck below the lightweight concrete). <br /> Warranty Design Enhancements, in the Sure-Weld Design <br /> Criteria Specification. 3. Structaral Concrete, rated 3,000 psi or greater — <br /> Carlisle CD-10 or HD 14-10 Fasteners (with Piranha <br /> PART II PRODUCTS Plates) are required with a minimum pullout of 800 <br /> 2.01 GENERAL pounds per fastener <br /> The components of this roofing system are to be products of 4 Wood Plank, minimum 15/32 thick Plywood - Carlisle <br /> Carlisle or accepted by Carlisle as compatible. T'he installation, HP-X Fasteners/Piranha Plates are required <br /> performance or integrity of products by others, w6en selected by <br /> the specifier and accepted by Carlisle, is not the responsibility 5 On oriented strand boazd (OSB) decks, HP-X Fasteners <br /> of Cazlisle and is expressly disclaimed by the Carlisle Warranty and Pirahna Plates may be used providing a pullout of <br /> z <br /> 600319 SWMF Guide - 2/2006 <br />