Laserfiche WebLink
�Rhvac - R�si�al 8 upM Co�1 HvAC I..osds Eila 8dtwan DwNopment, lnc. <br /> • Lh� Be�aon Bojac�c ■ 2EPFiYRHiLtS Ctuxoh Of Christ <br /> Cietrtant, FL 34711 Pa�e 4 <br /> �; Tot /a B iu ldi� Summary Loads � __� <br /> � � -� �� � '�� <br /> . � ��� �--, -�' `� <br /> Z CHURCH: Glazing-CHURCH 3X5 WINDOW, u-value 105 1,106 0 2,906 2,906 <br /> 0.35, SHGC 0.32 <br /> Z CHURCH: Door-Wood - Panel 40 192 0 172 172 <br /> 13A-4fcb: Wall-Biock, board insulation only, R-4 board 415 1,494 0 811 811 � <br /> insulation, filled core, brick finish � <br /> 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 600 576 0 787 787 'i <br /> Floor (also use for Knee Walls and PartRion ; <br /> Ceilings), Vented Attic, No Radiant Barrier, White or <br /> Light Color Shingles, Any Wood Shake, Light Metal, <br /> Tar and Gravel or Membrane, R-30 insulation <br /> 22A-pl: Floor-Slab on grade, No edge insulation, no 70 2,077 0 0 0 i, <br /> insulation below floor, any floor cover, passive, light i <br /> dry soil , <br /> Subtotals for structure: 5,445 0 4,676 4,676 �'�, <br /> People: 30 6,000 6,900 12,900 I <br /> Equipment: 0 0 0 j <br /> Lighting: 0 0 0 ': <br /> Ductwork: 1,508 376 1,885 2,261 i� <br /> Infiltration: Winter CFM: 62, Summer CFM: 53 2,032 1,917 937 2,854 i <br /> Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0! <br /> AED Excursion: 0 0 103 103 i <br /> Total Building Load Totals: 8,985 8,293 14,501 22,794 i <br /> C�ti� � <br /> Total Building Supply CFM: 660 CFM Per Square ft.: 1.099 I <br /> Square ft, of Room Area: 600 Square ft. Per Ton: 316 � <br /> Volume (ft') of Cond. Space: 4,800 �� <br /> Total HeaUng Required Including Ventilation Air: 8,985 Btuh 8.985 MBH <br /> Total Sensible Gain: 14,501 Btuh 64 °� <br /> Total Latent Gain: 8,293 Btuh 36 % <br /> Total Cooling Required Incfuding Ventilation Air: 22,794 Btuh 1.90 Tons (Based On Sensible + Latent) <br /> � <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> � Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> � <br /> I <br /> I <br /> � <br /> ,, , <br /> � <br /> � <br /> I <br /> i <br /> C:\ ...�ZEPHYRHILLS CHURCH OF CHRIST.rh9 Wednesday, June 15, 2011, 8:43 PM <br />